Evaluation of a system for on-line analysis of VO2 and VCO2 for clinical applicability.

Y Shimada, I Yoshiya, T Hirata, J Takezawa, N Taenaka.   

Abstract

The authors evaluated the accuracy of a system to measure respiratory gas exchange on an on-line basis by comparing it with a gas collection method. The system incorporates a hot-wire flowmeter, a mass spectrometer, and a microcomputer. It performs on-line compensation for both transport delay and dynamic response of the mass spectrometer. Compensation of flow measurement for changing gas fractions also is performed. Excellent linear correlations were obtained between the two methods: 1) in animals during mechanical ventilation with room air (VO2:r = 0.995; VCO2:r = 0.993), and nitrous oxide in oxygen (VO2:r = 0.975; VCO2:r = 0.976); and 2) in men spontaneously breathing room air at different workloads (VO2:r = 0.999; VCO2:r = 0.998), and higher inspired oxygen fractions (FIO2 0.38 to 0.75) (VO2:r = 0.910; VCO2:r = 0.988). The authors consider that the system is suited for accurate and continuous measurement of respiratory gas exchange during mechanical ventilation, anesthesia, and exercise testing.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6433749     DOI: 10.1097/00000542-198409000-00009

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  6 in total

1.  Effects of daily activity recorded by pedometer on peak oxygen consumption (VO2peak), ventilatory threshold and leg extension power in 30- to 69-year-old Japanese without exercise habit.

Authors:  Jian-Guo Zhang; Toshiki Ohta; Kazuko Ishikawa-Takata; Izumi Tabata; Mitsumasa Miyashita
Journal:  Eur J Appl Physiol       Date:  2003-06-21       Impact factor: 3.078

2.  Mass spectrometer system for long-term continuous measurements of v.O2 and v.CO2 during artificial ventilation.

Authors:  O Bertrand; J P Viale; G Annat; F Sebes; B Delafosse; C Percival; B Bui-Xuan; J Motin
Journal:  Med Biol Eng Comput       Date:  1986-03       Impact factor: 2.602

3.  Calculation of O2 consumption during low-flow anesthesia from tidal gas concentrations, flowmeter, and minute ventilation.

Authors:  Takafumi Azami; David Preiss; Ron Somogyi; Alex Vesely; Eitan Prisman; Steve Iscoe; Andre M De Wolf; Joseph A Fisher
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

4.  Ratings of perceived exertion in chronic obstructive pulmonary disease--a possible indicator for exercise training in patients with this disease.

Authors:  M Chida; N Inase; M Ichioka; I Miyazato; F Marumo
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

5.  Functional residual capacity measurement during tracheal gas insufflation.

Authors:  Y Fujino; M Nishimura; O Hirao; N Taenaka; I Yoshiya
Journal:  J Clin Monit Comput       Date:  1998-05       Impact factor: 2.502

6.  Factors affecting lower limb muscle strength and cardiopulmonary fitness after allogeneic hematopoietic stem cell transplantation.

Authors:  Aiko Ishikawa; Yohei Otaka; Michiyo Kamisako; Tetsuya Suzuki; Chieko Miyata; Tetsuya Tsuji; Hideo Matsumoto; Jun Kato; Takehiko Mori; Shinichiro Okamoto; Meigen Liu
Journal:  Support Care Cancer       Date:  2018-08-28       Impact factor: 3.603

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.