Literature DB >> 6433711

Hypoxemia during hemodialysis using acetate versus bicarbonate dialysate.

D K Abu-Hamdan, S G Desai, S K Mahajan, B F Muller, W A Briggs, P Lynne-Davies, F D McDonald.   

Abstract

To evaluate the extent and cause(s) of dialysis-related hypoxemia, we studied 10 patients, 7 days apart using acetate (AC) and bicarbonate dialysate (HCO3). We measured arterial blood gases, WBC, minute ventilation (VE) and inspired and expired gas concentrations and calculated the respiratory quotient (R) and the alveolar-arterial oxygen difference (A-a)DO2 before and during hemodialysis. 8 patients developed hypoxemia. Arterial PO2 (PaO2) dropped similarly at 30 min from 93 +/- 5 to 78 +/- 6 (p less than 0.05) and 89 +/- 4 to 79 +/- 5 mm Hg (p less than 0.05) with AC and HCO3, respectively. R and VE decreased during AC (p less than 0.05). (A-a)DO2 increased at 30 min and correlated with the drop in PaO2 during both AC (r = 0.68, p less than 0.025) and HCO3 (r = 0.76, p less than 0.025). The fall in PaO2 also correlated with the fall in WBC count for both AC and HCO3 (r = 0.63, p less than 0.005). The increase in arterial pH during HCO3 (up to 7.45 +/- 0.01) was significantly greater than that during AC (up to 7.42 +/- 0.01) (p less than 0.025), and coincided with a relative decrease in VE. We conclude that (1) HCO3 does not prevent hypoxemia, and (2) hypoventilation V/Q abnormalities and increase in arterial pH, contribute variably to dialysis related hypoxemia depending on the type of dialysate and the time during dialysis.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6433711     DOI: 10.1159/000166818

Source DB:  PubMed          Journal:  Am J Nephrol        ISSN: 0250-8095            Impact factor:   3.754


  3 in total

Review 1.  The lungs in uraemia: a review.

Authors:  A Bush; R Gabriel
Journal:  J R Soc Med       Date:  1985-10       Impact factor: 5.344

2.  Microcirculatory changes and skeletal muscle oxygenation measured at rest by non-infrared spectroscopy in patients with and without diabetes undergoing haemodialysis.

Authors:  Roberto Alberto De Blasi; Remo Luciani; Giorgio Punzo; Roberto Arcioni; Rocco Romano; Marta Boezi; Paolo Menè
Journal:  Crit Care       Date:  2009-11-30       Impact factor: 9.097

3.  Effects of high versus low flux membranes on o2 saturation in hemodialysis patients.

Authors:  Ali Momeni; Hamid Rouhi; Masoud Amiri
Journal:  Nephrourol Mon       Date:  2012-12-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.