Literature DB >> 6403597

A novel immunoradiometric assay for human liver ferritin.

A Al-Shawi, A Dawnay, J Landon.   

Abstract

Rivanol, the cationic salt of an acridine base, has been used as a novel separation procedure in an immunoradiometric assay for human liver ferritin. The separation step is based on the differences in charge and molecular weight between the labelled antibody-ferritin complex and free labelled immunoglobulins. The resultant assay is simple, reproducible and sufficiently sensitive to determine serum concentrations of ferritin.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6403597      PMCID: PMC498241          DOI: 10.1136/jcp.36.4.440

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  7 in total

1.  The isolation of gamma globulin from blood-serum by rivanol.

Authors:  J HOREJSI; R SMETANA
Journal:  Acta Med Scand       Date:  1956-06-30

2.  Protein measurement with the Folin phenol reagent.

Authors:  O H LOWRY; N J ROSEBROUGH; A L FARR; R J RANDALL
Journal:  J Biol Chem       Date:  1951-11       Impact factor: 5.157

Review 3.  Properties, variants, and applications of the immunoradiometric assay method.

Authors:  L E Miles
Journal:  Ric Clin Lab       Date:  1975 Jan-Mar

4.  The cross-linking of proteins with glutaraldehyde and its use for the preparation of immunoadsorbents.

Authors:  S Avrameas; T Ternynck
Journal:  Immunochemistry       Date:  1969-01

5.  Labelled antibodies and immunological assay systems.

Authors:  L E Miles; C N Hales
Journal:  Nature       Date:  1968-07-13       Impact factor: 49.962

6.  Isolation of ferritin from human mammary and pancreatic carcinomas by means of antibody immunoadsorbents.

Authors:  D M Marcus; N Zinberg
Journal:  Arch Biochem Biophys       Date:  1974-06       Impact factor: 4.013

7.  The effect of chaotropic ions on the dissociation of antigen-antibody complexes.

Authors:  W B Dandliker; R Alonso; V A de Saussure; F Kierszenbaum; S A Levison; H C Schapiro
Journal:  Biochemistry       Date:  1967-05       Impact factor: 3.162

  7 in total
  1 in total

Review 1.  Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.

Authors:  Maria N Garcia-Casal; Juan P Peña-Rosas; Eloisa Urrechaga; Jesus F Escanero; Junsheng Huo; Ricardo X Martinez; Lucero Lopez-Perez
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.