Literature DB >> 6396212

Electrical and acoustic properties of biological materials and biomedical applications.

H P Schwan.   

Abstract

Mesh:

Year:  1984        PMID: 6396212     DOI: 10.1109/TBME.1984.325251

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


× No keyword cloud information.
  8 in total

1.  Dependence of anisotropic myocardial electrical resistivity on cardiac phase and excitation frequency.

Authors:  P Steendijk; E T van der Velde; J Baan
Journal:  Basic Res Cardiol       Date:  1994 Sep-Oct       Impact factor: 17.165

2.  Differentiation of the intracellular structure of slow- versus fast-twitch muscle fibers through evaluation of the dielectric properties of tissue.

Authors:  B Sanchez; J Li; R Bragos; S B Rutkove
Journal:  Phys Med Biol       Date:  2014-04-17       Impact factor: 3.609

3.  Separation of Subcutaneous Fat From Muscle in Surface Electrical Impedance Myography Measurements Using Model Component Analysis.

Authors:  Hyeuknam Kwon; Wasim Q Malik; Seward B Rutkove; Benjamin Sanchez
Journal:  IEEE Trans Biomed Eng       Date:  2018-05-23       Impact factor: 4.538

Review 4.  Electrical impedance myography: A critical review and outlook.

Authors:  Benjamin Sanchez; Orjan G Martinsen; Todd J Freeborn; Cynthia M Furse
Journal:  Clin Neurophysiol       Date:  2020-12-03       Impact factor: 3.708

5.  A Novel Application for Low Frequency Electrochemical Impedance Spectroscopy as an Online Process Monitoring Tool for Viable Cell Concentrations.

Authors:  Christoph Slouka; David J Wurm; Georg Brunauer; Andreas Welzl-Wachter; Oliver Spadiut; Jürgen Fleig; Christoph Herwig
Journal:  Sensors (Basel)       Date:  2016-11-11       Impact factor: 3.576

6.  Permittivity of ex vivo healthy and diseased murine skeletal muscle from 10 kHz to 1 MHz.

Authors:  J A Nagy; C J DiDonato; S B Rutkove; B Sanchez
Journal:  Sci Data       Date:  2019-04-18       Impact factor: 6.444

7.  Electrical Characterization of Basal Cell Carcinoma Using a Handheld Electrical Impedance Dermography Device.

Authors:  Xuesong Luo; Ye Zhou; Tristan Smart; Douglas Grossman; Benjamin Sanchez
Journal:  JID Innov       Date:  2021-11-26

8.  Endoscopic-Guided Measurement of Mucosal Admittance can Discriminate Gastroesophageal Reflux Disease from Functional Heartburn.

Authors:  Tomoaki Matsumura; Hideaki Ishigami; Mai Fujie; Takashi Taida; Shingo Kasamatsu; Kenichiro Okimoto; Keiko Saito; Daisuke Maruoka; Tomoo Nakagawa; Takeshi Suzuki; Tatsuro Katsuno; Makoto Arai
Journal:  Clin Transl Gastroenterol       Date:  2017-06-01       Impact factor: 4.488

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.