Reverse-flow apparatus for enhanced colorimetric detection of bacteriuria.

C Wallis, J L Melnick.   

Abstract

The reverse-flow apparatus is a new device for enhancing the detection of bacteria in urine. Bacteria are trapped onto a customized filter, and the pigments, crystals, and other interfering substances in the urine pass through the filter and are discarded. The bacteria are backflushed and are recovered as a concentrate, and the concentrate is then processed through the previously described colorimetric bacteriuria detection device. A total of 1,000 urine samples were obtained from randomly selected patients and were cultured on agar. Upon enumeration of the colonies, 160 urine samples were shown to contain more than 10(5) CFU/ml. In the bacteriuria detection device, 150 urine samples could not be processed (pigmenters and cloggers), and of the 850 urine samples processed, 127 were culture positive for 10(5) CFU/ml or greater, and 150 urine samples contained between 10(4) and 10(5) CFU/ml. At 10(5) CFU/ml, there were 140 false-positives and 14 false-negatives. When duplicate urine samples were processed through and concentrated by our new reverse-flow apparatus, all samples, including the above pigmenters and cloggers, could be tested in the bacteriuria detection device. The 150 unprocessable samples described above yielded 33 additional bacteria-positive urines, 23 at the 10(5)-CFU/ml cutoff and 10 at the 10(4)-to-10(5)-CFU/ml cutoff. There were 105 false-positives at 10(5) CFU/ml and only 2 false-negatives at the same level of bacteria. At 10(4) to 10(5) CFU/ml there was only 1% false-positive and 4% false-negative. The reverse-flow apparatus allows greater specificity and sensitivity in the rapid bacteriuria test. Urine containing 10(4) CFU/ml or more can now be detected with a 96% sensitivity in a total processing time of less than 2 min.

Entities:  

Mesh:

Year:  1984        PMID: 6392325      PMCID: PMC271479          DOI: 10.1128/jcm.20.5.942-944.1984

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Clinical laboratory evaluation of a urine screening device.

Authors:  M A Pfaller; C A Baum; A C Niles; P R Murray
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

2.  Evaluation of a two-minute test for urine screening.

Authors:  M T Pezzlo; M A Wetkowski; E M Peterson; L M de la Maza
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

3.  Problems of spectrum and bias in evaluating the efficacy of diagnostic tests.

Authors:  D F Ransohoff; A R Feinstein
Journal:  N Engl J Med       Date:  1978-10-26       Impact factor: 91.245

4.  Colorimetric method for rapid determination of bacteriuria.

Authors:  C Wallis; J L Melnick; C J Longoria
Journal:  J Clin Microbiol       Date:  1981-09       Impact factor: 5.948

  4 in total
  1 in total

1.  Rapid, colorimetric method for the detection of microorganisms in blood culture.

Authors:  C Wallis; J L Melnick
Journal:  J Clin Microbiol       Date:  1985-04       Impact factor: 5.948

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.