Literature DB >> 639220

Long-term mitral valve replacement in young children. Influence of somatic growth on prosthetic valve adequacy.

S Friedman, L H Edmunds, C C Cuaso.   

Abstract

Long-term clinical and laboratory findings in three children who required mitral valve replacement below age four years are reported. In each instance a second valve replacement was necessary approximately 8 1/2 years after the initial one, following a two and one-half fold increase in body weight. Inadequate mitral valve orifice size was found in each instance, producing a hemodynamic picture equivalent to mitral stenosis: congestive heart failure, pulmonary hypertension and atrial fibrillation. A second valve was placed without mortality in each instance and relieved the mitral valve obstruction. Pulmonary vascular resistance increased postoperatively in two patients and failed to decrease in the third. Pulmonary arterial hypertension and left ventricular hypertrophy persisted as long as 13 to 37 months after the second valve placement in all patients. The consequences of increasing body size and the long-term interposition of a rigid prosthesis in a growing heart introduce additional complications to mitral valve replacement in childhood. Frequent hemodynamic observations and the use of a prosthesis other than the ball-cage variety is recommended for improved management.

Entities:  

Mesh:

Year:  1978        PMID: 639220     DOI: 10.1161/01.cir.57.5.981

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  3 in total

1.  Valve replacement in children.

Authors:  M J Elliott; M de Leval
Journal:  World J Surg       Date:  1985-08       Impact factor: 3.352

2.  Premeditated reoperation after mitral valve replacement with a Starr-Edwards ball valve for young women who desire to bear a child: report of two cases.

Authors:  Ryota Asano; Kiyoharu Nakano; Kojiro Kodera; Noriyuki Murai; Akihito Sasaki; Masahiro Ikeda; Go Kataoka; Akiko Yamaguchi; Satoru Domoto; Yasuo Takeuchi
Journal:  Surg Today       Date:  2009-07-29       Impact factor: 2.549

3.  Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

Authors:  Seung Hyun Lee; Byung Chul Chang; Young-Nam Youn; Hyun Chel Joo; Kyung-Jong Yoo; Sak Lee
Journal:  J Cardiothorac Surg       Date:  2017-10-10       Impact factor: 1.637

  3 in total