Literature DB >> 6391303

Pressure and volume measurements from the eye for detecting possible arterial obstruction.

L P McRae, M M Kartchner.   

Abstract

Detection and evaluation of functionally significant carotid occlusive disease are effectively achieved by noninvasive pressure and/or volume measurements from the eye. Ocular arterial blood pressure is measured by applying either direct compression or suction to evaluate intraocular pressure to the point of arterial collapse. Carotid blood flow is evaluated as it affects ocular volume waveforms, which result from the difference between pulsatile arterial flow and relatively constant venous flow. The relationship between noninvasive measurements from the eyes and carotid blood flow can be predicted using simple models of the cervical-cerebral circulatory system. Proper models verify clinically observed correlations between pressure and volume measurements from the eye and the underlying carotid occlusive disease. Electrical analog circuits provide a method for varying model parameters to simulate abnormalities, producing waveforms with good similarity to waveforms recorded from patients with known vascular or ophthalmic pathology. Further model refinements can be contributed by interested investigators. By using the improved models the strengths and weaknesses of current tests and techniques can then be better defined. Techniques that have been widely used for screening and evaluating potential stroke patients can thereby be modified to give improved functional analysis of these patients.

Entities:  

Mesh:

Year:  1984        PMID: 6391303     DOI: 10.1007/BF02410292

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  12 in total

1.  A HANDY INSTRUMENT FOR OCULO-SPHYGMOGRAPHY WITH SOME CLINICAL RESULTS.

Authors:  H G BYNKE; C E KRAKAU
Journal:  Ophthalmologica       Date:  1964       Impact factor: 3.250

2.  [Electronic ocular sphygmo-oscillograph].

Authors:  E ZENATTI
Journal:  Ann Ocul (Paris)       Date:  1950-11

3.  Simultaneous carotid-ophthalmic pulse wave recording.

Authors:  G E Martin; R H Barnes; P S Montgomery
Journal:  Cardiologia       Date:  1967

4.  Ocular pneumoplethysmography in carotid artery disease.

Authors:  W Gee; C A Smith; C E Hinson; E J Wylie
Journal:  Med Instrum       Date:  1974 Jul-Aug

5.  The ocular pulse.

Authors:  M A Galin; M Best; G Plechaty; P Nussbaum
Journal:  Trans Am Acad Ophthalmol Otolaryngol       Date:  1972 Nov-Dec

6.  Noninvasive detection and evaluation of carotid occlusive disease.

Authors:  M M Kartchner; L P McRae; F D Morrison
Journal:  Arch Surg       Date:  1973-04

7.  Ophthalmodynamometry and ophthalmodynamography in subclavian steal syndrome.

Authors:  P Follmann; J Littmann; L Urai; S Heszberger
Journal:  Ophthalmologica       Date:  1969       Impact factor: 3.250

8.  Screening diagnosis of carotid occlusion by means of oculosphygmography.

Authors:  H G Bynke
Journal:  Neurology       Date:  1966-04       Impact factor: 9.910

9.  Graphic analysis of the ocular pulse in carotid occlusion.

Authors:  M Best; M Keyes; G Plechaty; M A Galin
Journal:  Arch Ophthalmol       Date:  1971-03

10.  Ophthalmodynamometry using suction.

Authors:  M A Galin; I Baras; R Cavero
Journal:  Arch Ophthalmol       Date:  1969-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.