Literature DB >> 6388458

Role of electrophysiologic testing in the preoperative evaluation of corneal transplant patients.

R T Wendel, M J Mannis, J L Keltner.   

Abstract

We performed preoperative skin electrode bright-flash ERG and VEP testing on 32 patients undergoing elective penetrating keratoplasty. Twenty-six patients had unilaterally decreased vision and six had bilateral visual impairment. By combining our quantitative electroretinogram (ERG) and qualitative visual evoked potential (VEP) results with clinical findings, we were able to predict visual outcome in 92% of cases. Our findings suggest that bright-flash ERG and VEP testing are useful adjunct studies to clinical and ultrasound findings in patients with media opacities, comparison of a and b wave amplitudes with the fellow eye may yield prognostic information, a normal ERG and VEP in the presence of an equivocal afferent pupillary defect may signal a good visual prognosis, and ERG and VEP are not reliably predictive in patients with media opacity and amblyopia or macular disease.

Entities:  

Mesh:

Year:  1984        PMID: 6388458

Source DB:  PubMed          Journal:  Ann Ophthalmol        ISSN: 0003-4886


  2 in total

1.  Preoperative prediction of postoperative visual acuity in patients with cataracts: a quantitative review.

Authors:  J V Odom; G M Chao; G W Weinstein
Journal:  Doc Ophthalmol       Date:  1988-09       Impact factor: 2.379

2.  Visually evoked potentials in a patient with a fyodorov-zuev keratoprosthesis.

Authors:  Roy Schwartz; Adiel Barak; Hadas Newman
Journal:  Case Rep Ophthalmol       Date:  2015-01-14
  2 in total