| Literature DB >> 6383704 |
M Fukushima, M Inoue, M Fukunami, K Ishikawa, H Inada, H Abe.
Abstract
A computer-assisted education system for arrhythmia (CAESAR) was developed for students to acquire the ability to logically diagnose complicated arrhythmias. This system has a logical simulator of cardiac rhythm using a mathematical model of the impulse formation and conduction system of the heart. A simulated arrhythmia (ECG pattern) is given on a graphic display unit with simulated series of the action potential of five pacemaker centers and the "ladder diagram" of impulse formation and conduction, which show the mechanism of that arrhythmia. For the purpose of the evaluation of this system, 13 medical students were given two types of tests concerning arrhythmias before and after 2-hr learning with this system. The scores they obtained after learning increased significantly from 73.3 +/- 11.9 to 93.2 +/- 3.0 (P less than 0.001) in one test and from 47.2 +/- 17.9 to 64.9 +/- 19.6 (P less than 0.001) in another one. These results proved that this CAI system is useful and effective for training ECG interpretation of arrhythmias.Entities:
Mesh:
Year: 1984 PMID: 6383704 DOI: 10.1016/0010-4809(84)90047-8
Source DB: PubMed Journal: Comput Biomed Res ISSN: 0010-4809