| Literature DB >> 6383120 |
J J Keyzer, B G Wolthers, F A Muskiet, H Breukelman, H F Kauffman, K de Vries.
Abstract
A new method for the determination of histamine by stable isotope dilution mass fragmentography is described. The method is specific, sensitive, and accurate, resulting in a within-day coefficient of variation of 4.1% and a day-to-day variation of 7.9%. It was shown that the first blood sample after a venipuncture can contain an artificially elevated plasma histamine concentration. Platelets contain about 7 pmol histamine/10(9) cells. Serum histamine was elevated about four times in comparison with plasma histamine. This phenomenon was mainly ascribed to degranulation of basophilic leukocytes by complement activation during blood clotting. Normal values for plasma histamine were (n = 25) 2.07 +/- 0.75 nmol/liter (mean +/- 1 SD), which is one of the lowest values reported up to now.Entities:
Mesh:
Substances:
Year: 1984 PMID: 6383120 DOI: 10.1016/0003-2697(84)90037-x