Literature DB >> 6365990

Cell content of goat milk: California mastitis test, Coulter counter , and fossomatic for predicting half infection.

B Poutrel, C Lerondelle.   

Abstract

The mean cell count of goat milk collected in early and midlactation from udder halves free of infection was 1404 X 10(3) cells/ml and 614 X 10(3) cells/ml estimated by Coulter Counter and Fossomatic. Arithmetic means of cell count by Fossomatic method for samples within California Mastitis Test scores were similar to results from cow milk. Results by the three methods were closely correlated .7. Means of cell counts were 2858 X 10(3) cells/ml and 1293 X 10(3) cells/ml by Coulter Counter and Fossomatic methods for udder halves harboring coagulase-negative staphylococci and 8946 X 10(3) cells/ml and 4804 X 10(3) cells/ml for halves infected by major pathogens. Of the thresholds examined, 1000 X 10(3) cells/ml was most satisfactory for both Coulter Counter and Fossomatic methods, because it detected about 80% of major infections and gave an acceptable proportion of errors.

Entities:  

Mesh:

Year:  1983        PMID: 6365990     DOI: 10.3168/jds.S0022-0302(83)82129-8

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  5 in total

1.  Comparison of morphology, viability, and function between blood and milk neutrophils from peak lactating goats.

Authors:  Sui Zhi Tian; Chai Ju Chang; Chih Chi Chiang; Huo Cheng Peh; Mu Chiou Huang; Jai-Wei Lee; Xin Zhao
Journal:  Can J Vet Res       Date:  2005-01       Impact factor: 1.310

2.  Microbicidal action of indole-3-acetic acid combined with horseradish peroxidase on Prototheca zopfii from bovine mastitis.

Authors:  Luciane T Cunha; Silvana M P Pugine; Marcia R M Silva; Ernane J X Costa; Mariza Pires De Melo
Journal:  Mycopathologia       Date:  2009-08-26       Impact factor: 2.574

3.  Direct and indirect measurement of somatic cell count as indicator of intramammary infection in dairy goats.

Authors:  Ylva Persson; Ida Olofsson
Journal:  Acta Vet Scand       Date:  2011-03-04       Impact factor: 1.695

4.  Hybrid microchannel-solid state micropore device for fast and optical cell detection.

Authors:  Carol M Olmos; Gustavo Rosero; Tamara Fernández-Cabada; Ross Booth; Manuel Der; Juan M Cabaleiro; Alexis Debut; Luis Cumbal; Maximiliano S Pérez; Betiana Lerner
Journal:  RSC Adv       Date:  2020-02-03       Impact factor: 4.036

5.  Selective individual primary cell capture using locally bio-functionalized micropores.

Authors:  Jie Liu; Radoslaw Bombera; Loïc Leroy; Yoann Roupioz; Dieudonné R Baganizi; Patrice N Marche; Vincent Haguet; Pascal Mailley; Thierry Livache
Journal:  PLoS One       Date:  2013-03-01       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.