Sinoatrial function after cardiac transplantation.

R S Bexton, A W Nathan, K J Hellestrand, R Cory-Pearce, R A Spurrell, T A English, A J Camm.   

Abstract

The function of both the denervated donor and innervated recipient sinus nodes of 14 asymptomatic cardiac transplant recipients was assessed. Tests of sinoatrial function were performed in 14 donor and 10 recipient atria. The mean spontaneous cycle length of the recipient atria was significantly longer than that of the donor atria (944 +/- 246 versus 663 +/- 158 ms, p less than 0.01). Donor sinus node recovery time was prolonged in four patients (greater than 2,500 ms in two) and recipient recovery time was prolonged in six patients. In those patients with normal sinus node function tests, the recovery time of the recipient sinus node was longer than that of the donor sinus node (1,170 +/- 207 versus 864 +/- 175 ms, p less than 0.02). The pattern of response of recovery times to increasing pacing rate was predictable and organized in the donor but chaotic in the recipient, and the longest sinus node recovery time occurred at the shortest pacing cycle length used in 12 of the 14 donor atria but in only 1 of the 10 recipient atria (p less than 0.001). Secondary pauses occurred in none of the normal donor atria and in all of the abnormal donor atria (p less than 0.001); however, they occurred in both normal and abnormal recipient atria. The recipient and donor atria were paced alone and synchronously in the same patients. Synchronous pacing had no effect on the recovery times of the donor sinus node but significantly lengthened those of the recipient (sinus node recovery time: 1,266 +/- 218 to 1,547 +/- 332 ms, p less than 0.02; corrected recovery time: 322 +/- 102 to 686 +/- 188 ms, p less than 0.01). In the donor atria, abnormal recovery time was invariably associated with abnormal sinoatrial conduction time. There was a strong correlation between sinoatrial conduction time measured by the methods of Strauss and Narula and their coworkers in the donor atria (r = 0.98, p less than 0.001) but not in the recipient atria (r = 0.72). In the absence of autonomic influences, tests of sinus node function of the donor atria produce predictable and consistent results and, therefore, may be more clinically reliable than in intact human subjects. There is a high incidence of recipient sinus node dysfunction in asymptomatic long-term survivors of cardiac transplantation.

Entities:  

Mesh:

Year:  1984        PMID: 6363487     DOI: 10.1016/s0735-1097(84)80247-8

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  The electrophysiology of cardiac allograft rejection: independent effects of rejection and perioperative ischemia on the sinus node recovery phenomenon after cardiac transplantation.

Authors:  G Heinz; M Hirschl; G Laufer; P Buxbaum; H Gössinger; P Siostrzonek; S Gasic; A Laczkovics
Journal:  Basic Res Cardiol       Date:  1992 Nov-Dec       Impact factor: 17.165

Review 2.  The mammalian sinoatrial node.

Authors:  T Opthof
Journal:  Cardiovasc Drugs Ther       Date:  1988-03       Impact factor: 3.727

3.  Nonpharmacologic validation of the intrinsic heart rate in cardiac transplant recipients.

Authors:  J S Strobel; A E Epstein; R C Bourge; J K Kirklin; G N Kay
Journal:  J Interv Card Electrophysiol       Date:  1999-03       Impact factor: 1.900

4.  Posttransplant pacemaker placement: case series and review.

Authors:  Mark A Thompson; Hamang Patel
Journal:  Ochsner J       Date:  2010

Review 5.  Migration of the true pacemaker within the sinoatrial cell aggregate in man.

Authors:  R M Negoescu
Journal:  Med Biol Eng Comput       Date:  1992-07       Impact factor: 2.602

6.  Effects of baroceptor and cardiopulmonary reflexes on neural control of heart rate in normal man, as assessed by power spectral analysis.

Authors:  F Macov; R Fagard; L Mortelmans; K Claeys; A Amery
Journal:  Clin Auton Res       Date:  1992-12       Impact factor: 4.435

7.  Permanent pacing after cardiac transplantation.

Authors:  C D Scott; J M McComb; J H Dark; R S Bexton
Journal:  Br Heart J       Date:  1993-05

Review 8.  Genetic Complexity of Sinoatrial Node Dysfunction.

Authors:  Michael J Wallace; Mona El Refaey; Pietro Mesirca; Thomas J Hund; Matteo E Mangoni; Peter J Mohler
Journal:  Front Genet       Date:  2021-04-01       Impact factor: 4.599

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.