Literature DB >> 6360373

Use of digitized functional angiography to evaluate arterial blood flow.

J H Bürsch.   

Abstract

Digital angiography (DA), being a computer-based imaging system, allows for manipulation of the image data. One potential use derived from data manipulation is the production of functional images or images that reflect a physiologic parameter in addition to anatomic information. A discussion is presented of the background work employed to derive blood flow measurements using DA images, including the theoretical and practical limitations of the methodology. While absolute blood flow is hard to determine by any noninvasive and many invasive methods, flow velocity and relative blood flow in large vessels is obtainable with small volumes of intraarterial contrast injection using the basic principles of indicator dilution techniques and evaluation of the time versus density relationships of contrast bolus. An appraisal of the functional imaging method is provided, including its drawbacks and the potential areas of application.

Mesh:

Year:  1983        PMID: 6360373     DOI: 10.1007/bf02552453

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

1.  DATA PROCESSING IN CARDIOVASCULAR PHYSIOLOGY WITH PARTICULAR REFERENCE TO ROENTGEN VIDEODENSITOMETRY.

Authors:  E H WOOD; R E STURM; J J SNDERS
Journal:  Mayo Clin Proc       Date:  1964-11       Impact factor: 7.616

2.  [Measurement and differential demonstration of renal blood flow by computer angiography (author's transl)].

Authors:  K H Höhne; M Böhm; W Erbe; G C Nicolae; G Pfeiffer; B Sonne; E Bücheler
Journal:  Rofo       Date:  1978-12

3.  Videodensitometric studies by a new method of quantitating the amount of contrast medium.

Authors:  J H Bürsch; P H Heintzen; R Simon
Journal:  Eur J Cardiol       Date:  1974-04

4.  Quantitative analysis of structure and function of the cardiovascular system by roentgen-video-computer techniques.

Authors:  P H Heintzen; R Brennecke; J H Bürsch; H J Hahne; P E Lange; K Moldenhauer; D Onnasch; W Radtke
Journal:  Mayo Clin Proc       Date:  1982-07       Impact factor: 7.616

5.  Assessment of arterial blood flow measurements by digital angiography.

Authors:  J H Bürsch; H J Hahne; R Brennecke; D Grönemeier; P H Heintzen
Journal:  Radiology       Date:  1981-10       Impact factor: 11.105

6.  Computer angiography: a new tool for x-ray functional diagnostics.

Authors:  K H Höhne; M Böhm; W Erbe; G C Nicolae; G Pfeiffer; B Sonne
Journal:  Med Prog Technol       Date:  1978-11-13
  6 in total
  4 in total

1.  Pulsatile coronary flow determination by digital angiography.

Authors:  H Marinus; B Buis; A van Benthem
Journal:  Int J Card Imaging       Date:  1990

2.  Absolute volumetric coronary blood flow measurement with digital subtraction angiography.

Authors:  S Molloi; G Bednarz; J Tang; Y Zhou; T Mathur
Journal:  Int J Card Imaging       Date:  1998-06

Review 3.  [New developments in parameter-oriented roentgen densitometry perfusion analysis within the scope of heart catheter studies].

Authors:  M Haude; G Caspari; D Baumgart; P Spiller; G Heusch; R Erbel
Journal:  Herz       Date:  1997-04       Impact factor: 1.443

Review 4.  Quantification in peripheral angiography.

Authors:  D P Harrington; K Kandarpa
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.