Literature DB >> 6357773

Detection by replica plating of false revertant colonies induced in the Salmonella-mammalian microsome assay by hexavalent chromium.

P Pedersen, E Thomsen, R M Stern.   

Abstract

The replica plating method as developed by Lederberg has been used to differentiate between "true" and "false" histidine-requiring revertant bacterial colonies which develop on minimal agar plates in the Ames test. Strains of S. typhimurium LT2, TA 100, when exposed to either sodium dichromate or the fumes from the welding of stainless steel, develop colonies whose apparent numbers are directly in proportion to the Cr(VI) content per plate in both cases, over a wide dose range. Replica impressions of the resulting colonies were transferred to Vogel Bonner minimal agar plates and incubated for 48 hr at 37 degrees C. It was then observed that considerable numbers of "false" revertant colonies were obtained at those Cr(VI) doses which resulted in a pronounced toxic effect, albeit with an acceptable level of the bacterial background lawn. No morphological distinction between "true" and "false" revertant colonies could be made. Although it would appear that at low doses (i.e., low toxicity) the true mutagenicity of stainless steel welding fumes can be completely accounted for by the presence of Cr(VI), the dose range over which the mutagenicity assay is reliable cannot be estimated from examination of the background lawn or from an estimate of the degree of survival of the treated cultures. Thus there is raised a serious question concerning the reliability of quantitative data published in bacterial mutagenicity testing where replica testing of the histidine requirement of the resulting "revertant" colonies is not routinely made. It is suggested that the replica technique can easily be developed as a simple and useful tool for the control of histidine requirement and ampicillin resistance in routine mutagenicity testing.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6357773      PMCID: PMC1569262          DOI: 10.1289/ehp.8351227

Source DB:  PubMed          Journal:  Environ Health Perspect        ISSN: 0091-6765            Impact factor:   9.031


  7 in total

1.  Detection of carcinogens as mutagens in the Salmonella/microsome test: assay of 300 chemicals.

Authors:  J McCann; E Choi; E Yamasaki; B N Ames
Journal:  Proc Natl Acad Sci U S A       Date:  1975-12       Impact factor: 11.205

2.  Replica plating and indirect selection of bacterial mutants.

Authors:  J LEDERBERG; E M LEDERBERG
Journal:  J Bacteriol       Date:  1952-03       Impact factor: 3.490

3.  Mutagenicity of fume particles from stainless steel welding.

Authors:  A Hedenstedt; D Jenssen; C Ramel; U Rannug; R M Stern
Journal:  Scand J Work Environ Health       Date:  1977-12       Impact factor: 5.024

4.  The Salmonella mutagenicity assay: recommendations.

Authors:  F J de Serres; M D Shelby
Journal:  Science       Date:  1979-02-09       Impact factor: 47.728

5.  Mutagenic activities of metal compounds in bacteria.

Authors:  H Nishioka
Journal:  Mutat Res       Date:  1975-06       Impact factor: 2.433

6.  Toxicity and mutagenicity of hexavalent chromium on Salmonella typhimurium.

Authors:  F L Petrilli; S De Flora
Journal:  Appl Environ Microbiol       Date:  1977-04       Impact factor: 4.792

7.  In vitro RPM fibrogenic potential assay of welding fumes.

Authors:  R M Stern; G H Pigott
Journal:  Environ Health Perspect       Date:  1983-09       Impact factor: 9.031

  7 in total
  1 in total

1.  In vitro assessment of equivalence of occupational health risk: welders.

Authors:  R M Stern
Journal:  Environ Health Perspect       Date:  1983-09       Impact factor: 9.031

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.