Literature DB >> 6354511

Temperature correction of blood-gas and pH measurements.

E R Ashwood, G Kost, M Kenny.   

Abstract

We critically review formulas for temperature correction of pH, pCO2, and pO2 measurements in whole blood and the clinical usefulness of these formulas. We discuss both the theoretical derivation and experimental verification of temperature-induced changes. We recommend when to use and when not to use these formulas, based upon the clinical interpretation of these assays.

Entities:  

Mesh:

Year:  1983        PMID: 6354511

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  25 in total

1.  Vagal amplification of phrenic nerve activity at different levels of ventilation in spontaneously breathing cats.

Authors:  C P van der Grinten; W R de Vries; S C Luijendijk
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

2.  Differential sensitivity to capture stress assessed by blood acid-base status in five carcharhinid sharks.

Authors:  John W Mandelman; Gregory B Skomal
Journal:  J Comp Physiol B       Date:  2008-10-10       Impact factor: 2.200

3.  Dynamic model of oxygen transport for transcutaneous PO2 analysis.

Authors:  A Talbot; M R Neuman; G M Saidel; E Jacobsen
Journal:  Ann Biomed Eng       Date:  1996 Mar-Apr       Impact factor: 3.934

4.  Underwater anesthesia of diamondback terrapins (Malaclemys terrapin) for measurement of auditory evoked potentials.

Authors:  Emily F Christiansen; Wendy E D Piniak; Lori A Lester; Craig A Harms
Journal:  J Am Assoc Lab Anim Sci       Date:  2013-11       Impact factor: 1.232

5.  Clinical assessment of a flow-through fluorometric blood gas monitor.

Authors:  G Bashein; J A Pino; M L Nessly; M A Kenny; K B Davis; T F Hornbein; T D Ivey
Journal:  J Clin Monit       Date:  1988-07

6.  In vitro assessment of a flow-through fluorometric blood gas monitor.

Authors:  J A Pino; G Bashein; M A Kenny
Journal:  J Clin Monit       Date:  1988-07

7.  Online pH, pCO2 and pO2 monitoring system using two-way cyclic pumping of lactate Ringer as a baseline solution.

Authors:  M Nakamura; M Yano; K Shibatani; Y Komoto
Journal:  Med Biol Eng Comput       Date:  1987-01       Impact factor: 2.602

8.  Oscillatory measurements, blood gas analysis and clinical observations after intravenous clenbuterol administration in healthy and acutely pneumonic calves.

Authors:  P Reinhold
Journal:  Vet Res Commun       Date:  1993       Impact factor: 2.459

9.  The relationship between the ventilation and lactate thresholds following normal, low and high carbohydrate diets.

Authors:  T M McLellan; G C Gass
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

10.  Conventional versus slug CO2 loading and the control of breathing in anaesthetized cats.

Authors:  C P van der Grinten; E Schoute; W R de Vries; S C Luijendijk
Journal:  J Physiol       Date:  1992-01       Impact factor: 5.182

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.