Literature DB >> 6348166

A computer-interfaced photometer and systematic spacing of duplicates to control within-plate enzyme-immunoassay variation.

B W Stemshorn, D J Buckley, G St Amour, C S Lin, J R Duncan.   

Abstract

A Multiskan photometer for reading microtiter plate enzyme immunoassays was linked with a time sharing computer to facilitate control of assay variation and analysis of results. The interface that converted photometer output to RS-232-C format required changes to divide the output into segments short enough for input to the computer. To measure within-plate variation and investigate how the method of allocating sample duplicates to plate wells may affect the estimation of sample variance, uniformity tests were conducted with 47 plates. Coefficients of variation (CV) among wells within-plates ranged from 4.6 to 20.7% and in two-thirds of the plates exceeded 10%. Duplicates allocated to adjacent wells (method 1) gave consistently higher CV for sample means than duplicates allocated to opposite plate quadrants (method 2). In general, the CV by method 2 was about 30% smaller than that by method 1. Analysis of variance confirmed the effectiveness of the quadrant pattern of duplicate allocation as a method of controlling variation that arises from well position effects.

Mesh:

Substances:

Year:  1983        PMID: 6348166     DOI: 10.1016/0022-1759(83)90233-8

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  12 in total

1.  Comparison of competitive and indirect enzyme-linked immunosorbent assays for detection of bluetongue virus antibodies in serum and whole blood.

Authors:  A Afshar; F C Thomas; P F Wright; J L Shapiro; P T Shettigara; J Anderson
Journal:  J Clin Microbiol       Date:  1987-09       Impact factor: 5.948

2.  Bovine brucellosis - diagnosis and eradication.

Authors:  B W Stemshorn
Journal:  Can Vet J       Date:  1985-01       Impact factor: 1.008

3.  Optimization and standardization of an enzyme-linked immunosorbent assay protocol for serodiagnosis of Actinobacillus pleuropneumoniae serotype 5.

Authors:  Y L Trottier; P F Wright; S Larivière
Journal:  J Clin Microbiol       Date:  1992-01       Impact factor: 5.948

4.  Human-isotype-specific enzyme immunoassay for antibodies to pneumococcal polysaccharides.

Authors:  G N Shyamala; D M Roberton; C S Hosking
Journal:  J Clin Microbiol       Date:  1988-08       Impact factor: 5.948

5.  Development and evaluation of an indirect enzyme immunoassay for detection of porcine antibodies to pseudorabies virus.

Authors:  A Afshar; P F Wright; G C Dulac
Journal:  Can J Vet Res       Date:  1986-07       Impact factor: 1.310

6.  Competitive and indirect enzyme-linked immunosorbent assays for Mycobacterium bovis infections based on MPB70 and lipoarabinomannan antigens.

Authors:  E A Sugden; K Stilwell; E B Rohonczy; P Martineau
Journal:  Can J Vet Res       Date:  1997-01       Impact factor: 1.310

7.  Enzyme-linked immunosorbent assay for detection of Salmonella lipopolysaccharide in poultry specimens.

Authors:  C E Rigby
Journal:  Appl Environ Microbiol       Date:  1984-06       Impact factor: 4.792

8.  Development of a competitive enzyme-linked immunosorbent assay for detection of bovine, ovine, porcine, and equine antibodies to vesicular stomatitis virus.

Authors:  A Afshar; N H Shakarchi; G C Dulac
Journal:  J Clin Microbiol       Date:  1993-07       Impact factor: 5.948

Review 9.  A review of enzyme immunoassay for detection of antibody to Brucella abortus in cattle.

Authors:  K H Nielsen; P F Wright; W A Kelly; J H Cherwonogrodzky
Journal:  Vet Immunol Immunopathol       Date:  1988-06       Impact factor: 2.046

10.  Routine and rapid enzyme linked immunosorbent assays for circulating anti-glomerular basement membrane antibodies.

Authors:  J Wheeler; J Simpson; A R Morley
Journal:  J Clin Pathol       Date:  1988-02       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.