Literature DB >> 6347690

CdTe-detector registration of 99mTc-DTPA clearance. An assessment of kidney function without blood sampling.

S Groth, A B Christensen, H Nielsen.   

Abstract

Since the most essential function of the kidneys is to regulate the composition and volume of the extracellular fluids the ratio of the extracellular volume (ECV) to the glomerular filtration rate (GFR) seems to be a relevant index of kidney function. This ratio is equal to the mean transit time (t) of an injected ECV-distributed tracer that is exclusively eliminated from the body by glomerular filtration. In 26 patients t was estimated by means of standard methods after an intravenous injection of 99mTc-DTPA and was found to be correlated (r = 0.98) to the reciprocal final slope of the time-activity curve obtained by means of small CdTe-detectors pasted laterally on the crus, 10-12 cm below the knee joint. It is concluded that this external measurement of kidney function, without blood sampling, may shorten the usual procedure from 4 to 1 h. Furthermore, due to the constant detection geometry throughout the investigation it may provide the means for prolonged continuous monitoring of the kidney function at steady state and when rapid changes are expected.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6347690     DOI: 10.1007/bf00522513

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  8 in total

1.  Volumes of distribution and clearances of intravenously injected creatinine in the dog.

Authors:  L A SAPIRSTEIN; D G VIDT; M J MANDEL; G HANUSEK
Journal:  Am J Physiol       Date:  1955-05

2.  Urinary clearance of 113m In-DTPA and 99mTc-(Sn)DTPA measured by external arm counting.

Authors:  M A Macleod; W F Sampson; A S Houston
Journal:  Urol Res       Date:  1977

3.  Measurement of extracellular volume and renal clearance by a single injection of inulin.

Authors:  H J Ladegaard-Pedersen
Journal:  Scand J Clin Lab Invest       Date:  1972-04       Impact factor: 1.713

4.  Effective renal plasma flow: estimation from theoretical volumes of distribution of intravenously injected 131-I orthoiodohippurate.

Authors:  W N Tauxe; F T Maher; W F Taylor
Journal:  Mayo Clin Proc       Date:  1971-08       Impact factor: 7.616

5.  Portable cadmium telluride detectors and their applicability for external measurement of 51Cr-EDTA clearance.

Authors:  J Bojsen; S Groth; N Rossing
Journal:  Int J Appl Radiat Isot       Date:  1981-10

6.  51Cr-EDTA clearance determined by one plasma sample.

Authors:  S Groth; M Aasted
Journal:  Clin Physiol       Date:  1981-08

7.  A simple method for the determination of glomerular filtration rate.

Authors:  J Bröchner-Mortensen
Journal:  Scand J Clin Lab Invest       Date:  1972-11       Impact factor: 1.713

8.  External monitoring of kidney transplant function using Tc-99m(Sn)DTPA.

Authors:  W F Sampson; M A Macleod; D Warren
Journal:  J Nucl Med       Date:  1981-05       Impact factor: 10.057

  8 in total
  2 in total

1.  Acute and long-term nephrotoxicity of cis-platinum in man.

Authors:  S Groth; H Nielsen; J B Sørensen; A B Christensen; A G Pedersen; M Rørth
Journal:  Cancer Chemother Pharmacol       Date:  1986       Impact factor: 3.333

2.  Comparative assessment of techniques for estimation of glomerular filtration rate with 99mTc-DTPA.

Authors:  R M Fawdry; S M Gruenewald; L T Collins; A J Roberts
Journal:  Eur J Nucl Med       Date:  1985
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.