| Literature DB >> 6345189 |
H R Schulten, P B Monkhouse, C Achenbach, R Ziskoven.
Abstract
Field desorption mass spectrometry (FD-MS) combined with stable isotope dilution has been used to determine rubidium concentrations from human serum. Samples obtained from 110 healthy volunteers (50 males, 60 females) were examined. The rubidium concentrations found varied from 0.96 to 3.56 mumoles/l, the average value being 1.96 mumoles/l. The precision of the measurements within a batch was 0.8%. The time for 1 analysis, including sample preparation is about 30 min, the total sample consumption is 100-200 mul. The corresponding potassium concentrations were also determined from all these serum samples; a weak trend towards higher potassium levels with increasing rubidium concentration is found.Entities:
Mesh:
Substances:
Year: 1983 PMID: 6345189 DOI: 10.1007/bf01990300
Source DB: PubMed Journal: Experientia ISSN: 0014-4754