Literature DB >> 6343447

Measurement of functional residual capacity during mechanical ventilation. Comparison of a computerized open nitrogen washout method with a closed helium dilution method.

J Ibañez, J M Raurich, S G Moris.   

Abstract

The functional residual capacity of patients treated with mechanical ventilation was measured with two methods: the closed helium dilution method and the open nitrogen washout method with a computerized system. Measurements of FRC were made with and without PEEP. The results obtained did not show significant differences between the methods. Additionally we checked the accuracy of the open nitrogen washout method to measure FRC of patients and healthy subjects breathing high concentrations of oxygen which was the same as breathing air. Both methods were equally reliable and safe when measuring the FRC of patients on mechanical ventilation but the nitrogen method was easier and quicker.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6343447     DOI: 10.1007/bf01699264

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  10 in total

1.  The measurement of the total lung volume and breathing capacity.

Authors:  J C GILSON; P HUGH-JONES
Journal:  Clin Sci       Date:  1949-04       Impact factor: 6.124

2.  Optimum end-expiratory airway pressure in patients with acute pulmonary failure.

Authors:  P M Suter; B Fairley; M D Isenberg
Journal:  N Engl J Med       Date:  1975-02-06       Impact factor: 91.245

3.  Ventilation with end-expiratory pressure in acute lung disease.

Authors:  K J Falke; H Pontoppidan; A Kumar; D E Leith; B Geffin; M B Laver
Journal:  J Clin Invest       Date:  1972-09       Impact factor: 14.808

4.  Studies of pulmonary insufficiency in non-thoracic trauma.

Authors:  S R Powers; R Burdge; R Leather; V Monaco; J Newell; S Sardar; E J Smith
Journal:  J Trauma       Date:  1972-01

5.  Functional residual capacity during anaesthesia. I: Methodology.

Authors:  A M Hewlett; G H Hulands; J F Nunn; K B Minty
Journal:  Br J Anaesth       Date:  1974-07       Impact factor: 9.166

6.  Determination of functional residual capacity during mechanical ventilation.

Authors:  P M Suter; R M Schlobohm
Journal:  Anesthesiology       Date:  1974-12       Impact factor: 7.892

7.  Effects of general anesthesia, muscle paralysis, and mechanical ventilation on pulmonary nitrogen clearance.

Authors:  K Rehder; D J Hatch; A D Sessler; H M Marsh; W S Fowler
Journal:  Anesthesiology       Date:  1971-12       Impact factor: 7.892

8.  Changes in functional residual capacity during respiratory failure.

Authors:  P R Ramachandran; H B Fairley
Journal:  Can Anaesth Soc J       Date:  1970-07

9.  A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation.

Authors:  J Ibañez; J M Raurich; S G Moris
Journal:  Crit Care Med       Date:  1982-05       Impact factor: 7.598

10.  Time course and mechanisms of lung-volume increase with PEEP in acute pulmonary failure.

Authors:  J A Katz; G M Ozanne; S E Zinn; H B Fairley
Journal:  Anesthesiology       Date:  1981-01       Impact factor: 7.892

  10 in total
  7 in total

1.  Automated measurement of functional residual capacity by sulfur hexafluoride washout.

Authors:  T D East; K P Andriano; N L Pace
Journal:  J Clin Monit       Date:  1987-01

2.  Monitoring of functional residual capacity by an oxygen washin/washout; technical description and evaluation.

Authors:  Dieter Weismann; Hajo Reissmann; Stefan Maisch; Bernd Füllekrug; Jochen Schulte
Journal:  J Clin Monit Comput       Date:  2006-07-11       Impact factor: 2.502

3.  The recording of FRC--is it of importance and can it be made simple?

Authors:  G Hedenstierna
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

4.  Normal values of functional residual capacity in the sitting and supine positions.

Authors:  J Ibañez; J M Raurich
Journal:  Intensive Care Med       Date:  1982       Impact factor: 17.440

5.  Lung volume in mechanically ventilated patients: measurement by simplified helium dilution compared to quantitative CT scan.

Authors:  Nicolò Patroniti; Giacomo Bellani; Annamaria Manfio; Elena Maggioni; Angela Giuffrida; Giuseppe Foti; Antonio Pesenti
Journal:  Intensive Care Med       Date:  2004-01-09       Impact factor: 17.440

6.  Measurement of functional residual capacity by helium dilution during partial support ventilation: in vitro accuracy and in vivo precision of the method.

Authors:  Fabiano Di Marco; Lidia Rota Sperti; Barbara Milan; Riccardo Stucchi; Stefano Centanni; Laurent Brochard; Roberto Fumagalli
Journal:  Intensive Care Med       Date:  2007-08-17       Impact factor: 17.440

7.  Measurement of end-expiratory lung volume by oxygen washin-washout in controlled and assisted mechanically ventilated patients.

Authors:  N Patroniti; M Saini; A Zanella; D Weismann; S Isgrò; G Bellani; G Foti; A Pesenti
Journal:  Intensive Care Med       Date:  2008-07-23       Impact factor: 17.440

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.