Literature DB >> 6341006

Fibrosis of experimental colonic anastomosis in dogs after EEA stapling or suturing.

P Buchmann, K Schneider, J O Gebbers.   

Abstract

Two out of five patients with a colonic anastomosis stapled with the EEA device, under protection of a diverting colostomy, developed stenosis requiring reoperation. Therefore, a canine experiment was conducted in order to compare the degree of fibrosis in a sutured with that in a stapled anastomosis. A colonic loop excluded from the fecal stream was transsected twice. One anastomosis was done by sutures, the other by an EEA stapling device. The amount of fibrous tissue between the circular muscle layer and the lamina muscularis mucosae was measured on strips of 2-mm length. Immediately after surgery, the submucosal edema was similar in both anastomoses. Marked fibrous thickening of stapled anastomoses developed after two to six months. In contrast, sutured anastomoses elicited very little fibrous thickening of the lamina submucosa. This difference in fibrosis could not be demonstrated following use of the stapling device alone, i.e., without staples. The fibrous thickening, measured in a stapled anastomosis diverted from the fecal stream, exceeds that seen in a sutured anastomosis and may result in stenosis. Therefore, it is suggested that an anastomosis, protected by a diverting colostomy, should be sutured.

Entities:  

Mesh:

Year:  1983        PMID: 6341006     DOI: 10.1007/bf02562480

Source DB:  PubMed          Journal:  Dis Colon Rectum        ISSN: 0012-3706            Impact factor:   4.585


  4 in total

1.  [Endoscopic therapy of benign anastomotic stenoses in the area of the colon and rectum by electro-incision and balloon dilatation].

Authors:  S Truong; B Klosterhalfen; G Arlt; H Mückter; V Schumpelick
Journal:  Langenbecks Arch Chir       Date:  1992

2.  [The blood supply of manually sutured and stapled colonic anastomoses].

Authors:  H Hansen; H J Sommer; W Eichelkraut
Journal:  Langenbecks Arch Chir       Date:  1987

3.  A new mechanical device for circular compression anastomosis. Preliminary results of animal and clinical experimentation.

Authors:  R Rosati; C Rebuffat; G Pezzuoli
Journal:  Ann Surg       Date:  1988-03       Impact factor: 12.969

4.  An analysis of the gene complement of a marsupial, Monodelphis domestica: evolution of lineage-specific genes and giant chromosomes.

Authors:  Leo Goodstadt; Andreas Heger; Caleb Webber; Chris P Ponting
Journal:  Genome Res       Date:  2007-05-10       Impact factor: 9.043

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.