Literature DB >> 633931

Acute thrombotic obstruction with Björk-Shiley valves: diagnostic and surgical considerations.

R J Moreno-Cabral, J J McNamara, R T Mamiya, S C Brainard, G K Chung.   

Abstract

Eight patients have had thrombotic obstruction of a prosthetic valve since 1971, six mitral valves and two aortic. All eight patients had a Björk-Shiley valve. During the same period 159 Björk-Shiley valves were placed, 85 in the mitral and 74 in the aortic area. This represents a valve thrombotic occlusive incidence of 4.4 percent in our series, 5.9 percent of mitral and 2.7 percent of aortic prostheses. Among the six patients with mitral prostheses only one survived. The two patients with occluded aortic valves survived. The onset of symptoms was very abrupt in most patients and progressed very rapidly. Acute pulmonary edema was observed in five patients. Anticoagulation was considered inadequate in all patients. Aspirin or dipyridamole was being used in seven patients at the time of thrombosis. The data indicate a high frequency of thrombotic occlusion of Björk-Shiley valves in the absence of full anticoagulation with warfarin derivatives and emphasizes the urgent need for surgery once valve thrombosis is suspected.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 633931

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

1.  Dysfunction of mechanical heart valve prosthesis: experience with surgical management in 48 patients.

Authors:  Wei-Guo Ma; Bin Hou; Adiljan Abdurusul; Ding-Xu Gong; Yue Tang; Qian Chang; Jian-Ping Xu; Han-Song Sun
Journal:  J Thorac Dis       Date:  2015-12       Impact factor: 2.895

2.  Detection of acute thrombosis of mitral tilting disk prosthesis by transesophageal echocardiography.

Authors:  P Ius; A Giacomin; A Cavarzerani; C Valfré
Journal:  Int J Card Imaging       Date:  1994-12

Review 3.  Thrombotic occlusion of Bjork-Shiley prosthetic aortic valve.

Authors:  Sumeesh Dhawan; Param Sharma; Tahir Tak
Journal:  Clin Med Res       Date:  2003-10

4.  Replacement of an immobile prosthetic mitral valve: a case report.

Authors:  A Mete; C Turkay; D Kumbasar; I Gölbaşi; N Sahin; O Bayezid
Journal:  Tex Heart Inst J       Date:  1999

5.  Thrombotic obstruction of the Björk-Shiley valve: the Glasgow experience.

Authors:  S J Ryder; H Bradley; J J Brannan; M A Turner; W H Bain
Journal:  Thorax       Date:  1984-07       Impact factor: 9.139

6.  Obstruction of mechanical valve prostheses: clinical diagnosis and surgical or nonsurgical treatment.

Authors:  S Aoyagi; S Fukunaga; S Suzuki; Y Nishi; A Oryoji; K Kosuga
Journal:  Surg Today       Date:  1996       Impact factor: 2.549

7.  Assessment of Björk-Shiley and porcine mitral valve dysfunction by m-mode echocardiographic left ventricular dimension.

Authors:  M G Eguaras; I M Luque; M Pan; A Montero; I Moriones; J Granados; M A Garcia; M Concha
Journal:  Tex Heart Inst J       Date:  1987-03

8.  Ionescu-Shiley pericardial xenograft valve: Hemodynamic evaluation and early clinical follow-up of 326 patients.

Authors:  David A. Ott; Aldemire T. Coelho; Denton A. Cooley; George J. Reul
Journal:  Cardiovasc Dis       Date:  1980-06
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.