Literature DB >> 6338216

The prosthodontic use of endodontically treated teeth: theory and biomechanics of post preparation.

K D DeSort.   

Abstract

It is impossible to state that any given system is better than another system for any and all situations. In all systems it is advisable to leave at least 3 to 5 mm of root canal filling to preserve the integrity of the apical seal. From a retentive standpoint, the parallel-sided posts have a greater retention than the tapering-sided posts but, because they are placed within a tapering root, they require more finesse on placement. In all teeth the length of the post is important since it is directly proportional to the amount of support offered by the post and its resistance to root fracture.

Entities:  

Mesh:

Year:  1983        PMID: 6338216     DOI: 10.1016/0022-3913(83)90501-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Effect of the ferrule on fracture resistance of teeth restored with prefabricated posts and composite cores.

Authors:  Annet Kutesa-Mutebi; Yusuf I Osman
Journal:  Afr Health Sci       Date:  2004-08       Impact factor: 0.927

2.  A simple antirotational mechanism in a posterior two piece post and core.

Authors:  Anup Gopi; R K Dhiman; Dinesh Kumar
Journal:  Med J Armed Forces India       Date:  2015-02-25

3.  Effect of Er:YAG laser pretreatment on bond strength of a composite core build-up material to fiber posts.

Authors:  Igor Križnar; Peter Jevnikar; Aleš Fidler
Journal:  Lasers Med Sci       Date:  2013-08-09       Impact factor: 3.161

4.  Influence of smear layer treatment on resistance to root fracture in tooth restored with epoxy fiber post.

Authors:  Satheesh B Haralur; Ali Hassan Al Faifi; Saed Saleh Al-Qahtani
Journal:  J Indian Prosthodont Soc       Date:  2013-06-19

5.  Does an intracanal composite anchorage replace posts?

Authors:  Gabriel Krastl; Andres Izquierdo; Leonard Büttel; Nicola U Zitzmann; Marc Schmitter; Roland Weiger
Journal:  Clin Oral Investig       Date:  2013-03-16       Impact factor: 3.573

6.  Stress analysis of a maxillary central incisor restored with different posts.

Authors:  Necdet Adanir; Sema Belli
Journal:  Eur J Dent       Date:  2007-04

7.  Evaluation of different post lengths' effect on fracture resistance of a glass fiber post system.

Authors:  Necdet Adanir; Sema Belli
Journal:  Eur J Dent       Date:  2008-01

8.  Multiple in vitro analyses of fracture resistance in maxillary central incisors restored with fiber posts.

Authors:  Fariborz Vafaee; Masoumeh Khoshhal; Aliakbar Rezaei; Fereidon Sooltani; Mohsen Jalalzadeh; Ali Yalpaniyan; Farnaz Firooz; Ali Reza Izady; Ebrahim Yarmohamadi
Journal:  Iran Endod J       Date:  2010-08-15

9.  Use of CAD/CAM in esthetic restoration of badly decayed tooth.

Authors:  Satheesh B Haralur; Ali Hassan Al-Faifi
Journal:  Case Rep Dent       Date:  2012-12-05
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.