Literature DB >> 6336104

Inherent sources of ultrasound variability in relation to follicular measurements.

G S Prins, R L Vogelzang.   

Abstract

Determination of ovarian follicular size and number by real-time ultrasound lacks the precision that has been ascribed to it. Four major error sources inherent in the scanning and interpreting process were analyzed to determine the relative contributions to overall variation. The sources measured were machine, sonographer, sonologist, and patient bladder volume. A protocol using a normal clomiphene-stimulated woman allowed the determination of the coefficient of variance for both follicular number and follicular diameter as well as a mean diameter range in each of the categories. A large degree of variation was found in all groups. Surprisingly, it was noted that maximal bladder filling did not produce optimal images. We believe that while variability in ultrasound can be recognized and lessened, it cannot be eliminated. Thus, caution must be used when ultrasound follicular comparisons are made within each program from day to day and particularly between institutions. A liberal range should be allowed for optimal follicle sizes for any given stimulation protocol.

Entities:  

Mesh:

Year:  1984        PMID: 6336104     DOI: 10.1007/bf01131620

Source DB:  PubMed          Journal:  J In Vitro Fert Embryo Transf        ISSN: 0740-7769


  6 in total

1.  Measurement of the ovarian follicle by ultrasound in ovulation induction.

Authors:  P Ylöstalo; L Rönnberg; P Jouppila
Journal:  Fertil Steril       Date:  1979-06       Impact factor: 7.329

2.  Evaluation of diagnostic ultrasound as a parameter of follicular development in an in vitro fertilization program.

Authors:  B Buttery; A Trounson; R McMaster; C Wood
Journal:  Fertil Steril       Date:  1983-04       Impact factor: 7.329

3.  Correlation of ultrasonic measurement of ovarian follicle size and serum estradiol levels in ovulatory patients following clomiphene citrate for in vitro fertilization.

Authors:  J M Vargyas; R P Marrs; O A Kletzky; D R Mishell
Journal:  Am J Obstet Gynecol       Date:  1982-11-01       Impact factor: 8.661

4.  Ultrasound scanning of ovaries to detect ovulation in women.

Authors:  J T Queenan; G D O'Brien; L M Bains; J Simpson; W P Collins; S Campbell
Journal:  Fertil Steril       Date:  1980-08       Impact factor: 7.329

5.  The role of ultrasound in ovulation induction: a critical appraisal.

Authors:  M M Seibel; C R McArdle; I E Thompson; M J Berger; M L Taymor
Journal:  Fertil Steril       Date:  1981-11       Impact factor: 7.329

6.  Correlation of ultrasonic and endocrinologic measurements in human menopausal gonadotropin therapy.

Authors:  R P Marrs; J M Vargyas; C M March
Journal:  Am J Obstet Gynecol       Date:  1983-02-15       Impact factor: 8.661

  6 in total
  1 in total

1.  Ultrasonic assessment of endometrial changes in stimulated cycles in an in vitro fertilization and embryo transfer program.

Authors:  B Smith; R Porter; K Ahuja; I Craft
Journal:  J In Vitro Fert Embryo Transf       Date:  1984-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.