Literature DB >> 6328631

Distribution and clearance of radioactive aerosol on the nasal mucosa.

J A McLean, J R Bacon, K P Mathews, J H Thrall, J M Banas, J Hedden, N K Bayne.   

Abstract

The distribution and clearance of aerosolized radioactive technetium 99m pertechnate in physiologic buffered saline was analyzed in four human adult asymptomatic volunteers following delivery into one nostril in the same manner as for nasal challenge testing (i.e., 0.1 ml via a 251 DeVilbiss atomizer powered by a compressor delivering 0.10 +/- 0.01 gm/spray). For comparison, squeeze bottles and spray bottles from commercial sources, a 114 and a 127 DeVilbiss atomizer, and a pipette were employed. Lateral imagery via minicomputer processing was used to determine both distribution and clearance of the radiotracer. The counts after 1 minute were lower following pipette delivery than with the other devices. None yielded discernable , wide-spread distribution of aerosol throughout the nasal cavity. Following delivery from the 251 atomizer, mean clearance at 17 minutes was 60.0%. Similar clearance rates were obtained with the other spraying methods except for lower values with the squeeze bottle. Analysis of six hour clearance studies by linear regression showed a relatively rapid initial phase, which is probably due largely to mucociliary clearance, and a prolonged late phase related to the very slow disappearance of residual material located far anteriorly in the nose. Achieving good initial retention and rapid clearance of material deposited anteriorly in the nose are desirable attributes of devices employed for administering materials intranasally.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6328631

Source DB:  PubMed          Journal:  Rhinology        ISSN: 0300-0729            Impact factor:   3.681


  4 in total

1.  Absorption and Clearance of Pharmaceutical Aerosols in the Human Nose: Effects of Nasal Spray Suspension Particle Size and Properties.

Authors:  Alex Rygg; Michael Hindle; P Worth Longest
Journal:  Pharm Res       Date:  2015-12-21       Impact factor: 4.200

2.  Absolute bioavailability of nicotine applied to different nasal regions.

Authors:  C J Johansson; P Olsson; M Bende; T Carlsson; P O Gunnarsson
Journal:  Eur J Clin Pharmacol       Date:  1991       Impact factor: 2.953

Review 3.  siRNA delivery to the lung: what's new?

Authors:  Olivia M Merkel; Israel Rubinstein; Thomas Kissel
Journal:  Adv Drug Deliv Rev       Date:  2014-06-05       Impact factor: 15.470

4.  Nasal drug delivery devices: characteristics and performance in a clinical perspective-a review.

Authors:  Per Gisle Djupesland
Journal:  Drug Deliv Transl Res       Date:  2012-10-18       Impact factor: 4.617