Literature DB >> 6325196

Clinical evaluation of 99mTc-pyrophosphate myocardial emission computed tomography: comparison with planar imaging.

N Tamaki, T Mukai, Y Ishii, Y Yonekura, D Hamanaka, K Minato, K Kadota, H Kambara, C Kawai, K Torizuka.   

Abstract

To depict the three-dimensional distribution of 99mTc-pyrophosphate in the heart, emission computed tomography (ECT) was performed, following the conventional planar imaging, in 32 cases with suspected acute myocardial infarction (AMI). There were 23 cases with evidence of AMI, 7 with unstable angina (UA), and 2 with dilated cardiomyopathy (DCM). While the planar images showed discrete cardiac activity in only 11 of the 23 cases (48%) with AMI, the ECT images delineated focal myocardial uptake clearly in 20 of them (87%). On the other hand, the ECT images revealed cardiac blood-pool activity without significant myocardial uptake in all cases with UA and DCM in which the planar images showed diffuse activity. Thus, the ECT imaging of 99mTc-pyrophosphate seems to be a valuable technique for assessing the presence and localization of myocardial necrosis, especially in cases showing diffuse cardiac activity in the planar imaging.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6325196     DOI: 10.1007/bf00253510

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  14 in total

1.  Technetium stannous pyrophosphate myocardial scintigrams in patients with chest pain of varying etiology.

Authors:  J T Willerson; R W Parkey; F J Bonte; S L Meyer; J M Atkins; E M Stokley
Journal:  Circulation       Date:  1975-06       Impact factor: 29.690

2.  A new method for radionuclide imaging of acute myocardial infarction in humans.

Authors:  R W Parkey; F J Bonte; S L Meyer; J M Atkins; G L Curry; E M Stokely; J T Willerson
Journal:  Circulation       Date:  1974-09       Impact factor: 29.690

3.  A new method for radionuclide imaging of myocardial infarcts.

Authors:  F J Bonte; R W Parkey; K D Graham; J Moore; E M Stokely
Journal:  Radiology       Date:  1974-02       Impact factor: 11.105

4.  Work in progress: a comparison of data collection protocols for single-photon emission tomography: 180 degrees versus 360 degrees.

Authors:  M H Lewis; F J Bonte; S E Lewis; E M Stokely
Journal:  Radiology       Date:  1982-11       Impact factor: 11.105

5.  Clinical evaluation of thallium-201 emission myocardial tomography using a rotating gamma camera: comparison with seven-pinhole tomography.

Authors:  N Tamaki; T Mukai; Y Ishii; Y Yonekura; H Kambara; C Kawai; K Torizuka
Journal:  J Nucl Med       Date:  1981-10       Impact factor: 10.057

6.  New approach to interpretation of technetium-99m pyrophosphate scintigraphy in detection of acute myocardial infarction: clinical assessment of diagnostic accuracy.

Authors:  D S Berman; E A Amsterdam; H H Hines; A F Salel; G J Bailey; G L DeNardo; D T Mason
Journal:  Am J Cardiol       Date:  1977-03       Impact factor: 2.778

7.  The specificity of the diffuse pattern of cardiac uptake in myocardial infarction imaging with technetium-99m stannous pyrophosphate.

Authors:  R Prasquier; M R Taradash; E H Botvinick; D M Shames; W W Parmley
Journal:  Circulation       Date:  1977-01       Impact factor: 29.690

8.  Limited clinical diagnostic specificity of technetium-99m stannous pyrophosphate myocardial imaging in acute myocardial infarction.

Authors:  M Ahmad; J P Dubiel; K W Logan; T A Verdon; R H Martin
Journal:  Am J Cardiol       Date:  1977-01       Impact factor: 2.778

9.  Measurement of infarct size using single photon emission computed tomography and technetium-99m pyrophosphate: a description of the method and comparison with patient prognosis.

Authors:  B L Holman; S Z Goldhaber; C M Kirsch; J F Polak; B J Friedman; R J English; J Wynne
Journal:  Am J Cardiol       Date:  1982-09       Impact factor: 2.778

10.  Myocardial infarct quantification in the dog by single photon emission computed tomography.

Authors:  J W Keyes; P F Leonard; S L Brody; D J Svetkoff; W L Rogers; B R Lucchesi
Journal:  Circulation       Date:  1978-08       Impact factor: 29.690

View more
  2 in total

1.  Clinical evaluation of positive myocardial imaging.

Authors:  T I Hale; A Jucker
Journal:  Eur J Nucl Med       Date:  1984

2.  Technetium-99m pyrophosphate tomogram of nontransmural myocardial infarction: a case report.

Authors:  C Kurata; K Sakata; T Taguchi; A Kobayashi; N Yamazaki
Journal:  Ann Nucl Med       Date:  1988-11       Impact factor: 2.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.