Literature DB >> 6318060

Beam scanning for heavy charged particle radiotherapy.

M Goitein, G T Chen.   

Abstract

An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam cross section. This paper examines the potential gain from the use of variable range modulation over the beam cross section which can be achieved through beam scanning. An analytic technique has been developed to calculate a gain factor, related to integral dose, for a number of different charged particle beams. The dependence of the gain factor on tumor depth, diameter, and size has been examined. These analytic results have been compared with computer calculations of treatment plans simulating beam scanning and fixed modulation delivery techniques for actual clinical cases. The rationale for beam scanning, and its potential impact on tumor control is discussed.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6318060     DOI: 10.1118/1.595419

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

Review 1.  Beam delivery systems for charged particles.

Authors:  H Blattmann
Journal:  Radiat Environ Biophys       Date:  1992       Impact factor: 1.925

Review 2.  Treatment planning with heavy ions.

Authors:  P Chauvel
Journal:  Radiat Environ Biophys       Date:  1995-03       Impact factor: 1.925

3.  Four-dimensional Monte Carlo simulations demonstrating how the extent of intensity-modulation impacts motion effects in proton therapy lung treatments.

Authors:  Stephen Dowdell; Clemens Grassberger; Harald Paganetti
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

4.  Interplay effects in proton scanning for lung: a 4D Monte Carlo study assessing the impact of tumor and beam delivery parameters.

Authors:  S Dowdell; C Grassberger; G C Sharp; H Paganetti
Journal:  Phys Med Biol       Date:  2013-05-20       Impact factor: 3.609

5.  Carbon-ion pencil beam scanning for thoracic treatment - initiation report and dose metrics evaluation.

Authors:  Masataka Karube; Shinichiro Mori; Hiroshi Tsuji; Naoyoshi Yamamoto; Mio Nakajima; Keiichi Nakagawa; Tadashi Kamada
Journal:  J Radiat Res       Date:  2016-07-05       Impact factor: 2.724

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.