Gold-195m, an ultra-short-lived generator-produced radionuclide: clinical application in sequential first pass ventriculography.

I Mena, K A Narahara, R de Jong, J Maublant.   

Abstract

Gold 195m (Au-195m) has a half-life of 30.5 sec and can be produced at the bedside from the parent mercury-195m (T 1/2 = 41.6 hr). The generator produced sterile pyrogen-free Au-195m with mercury breakthrough of 0.75 +/- 0.09 (s.e.m.) muCi per mCi of Au-195m. Approximately 20 to 25 mCi of Au-195m was produced per elution from a generator containing 155 mCi of Hg-195m. We compared first-pass resting Tc-99m angiograms with Au-195m angiograms in 28 patients. The correlation coefficient between the two studies was 0.92 over an ejection-fraction range from 0.22 to 0.83. In addition, we tested the reproducibility of Au-195m first-pass angiograms by performing two studies 3 min apart. In 25 patients with ejection fractions ranging from 0.20 to 0.78, the correlation coefficient between such pairs was 0.93. The nuclide is reliably and reproducibly produced, and its short half-life allows the performance of background-free sequential first-transit studies with unusually low radiation exposure to the patient.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6296336

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  Factor analysis in left ventricular first-pass radionuclide angiography: value of the ventricular factor to measure ejection fraction.

Authors:  J C Maublant; I Mena; L G Hanelin
Journal:  Int J Card Imaging       Date:  1985

2.  First-pass left ventricular ejection fraction with 95mAu on a 1/4 in. crystal gamma camera.

Authors:  B Shapiro; M Pillay; P H Cox; W J Remme
Journal:  Eur J Nucl Med       Date:  1984

3.  Feasibility of first-pass radionuclide angiocardiography with a 10-mCi technetium bolus using a single-crystal digital gamma camera: implications for technetium-sestamibi single-day protocols.

Authors:  J P Esquerré; F J Coca; P Gantet; E Ouhayoun
Journal:  Eur J Nucl Med       Date:  1995-06

4.  Biokinetics and dosimetry for 195Au, evaluated in an animal model.

Authors:  L Andersson; L Hallstadius; S E Strand
Journal:  Eur J Nucl Med       Date:  1988

5.  Quantification of intracardiac shunts by gold-195m, a new radionuclide with a short half life.

Authors:  D L Stone; R W Barber; O J Ormerod; M C Petch; E P Wraight
Journal:  Br Heart J       Date:  1985-11
  5 in total