Literature DB >> 6291945

Clinical evaluation of single photon emission computed tomography of the brain.

H Oyamada, S Terui, H Fukukita, H Kawai, K Nagaiwa.   

Abstract

Single photon emission computed tomography (ECT) was performed on 67 patients. ECT images were taken with a Shimadzu scintillation camera, LFOV-E, before a delayed scan. Eighteen of 67 patients showed abnormal findings on the ECT images. Fourteen of the 18 had a transmission X-ray CT (TCT) study as well. There were eleven cases with brain metastasis, and a surgical wound. Eleven of forty-nine ECT-negative patients had a TCT study as well, and intracranial lesions were found in five. The smallest lesion found by ECT was 0.5 cm in diameter on the TCT image and the largest lesion missed by ECT was a tumor in the corpus callosum, measuring 4.2 X 2.7 cm. As far as the patients who also received TCT study are concerned, both the ECT and the ordinary scan were thought to be equal in sixteen patients and ECT to be superior in seven whereas the ordinary scintigram was superior in two. At present, ECT is considered to be useful when it is used in addition to the ordinary scans. In the field of clinical nuclear medicine, the development of new radiopharmaceuticals which are labeled with single photon emitters and which can show the metabolic activity of the brain is eagerly awaited.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6291945     DOI: 10.1007/bf00253077

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  16 in total

1.  Computerized transverse axial scanning (tomography). 1. Description of system.

Authors:  G N Hounsfield
Journal:  Br J Radiol       Date:  1973-12       Impact factor: 3.039

2.  Cranial scintigraphy: value of adding emission computed tomographic sections to conventional pertechnetate images (512 cases).

Authors:  J M Carril; A F MacDonald; P P Dendy; W I Keyes; P E Undrill; J R Mallard
Journal:  J Nucl Med       Date:  1979-11       Impact factor: 10.057

3.  Three-dimensional regional cerebral blood perfusion images with single-photon emission computed tomography.

Authors:  T Maeda; H Matsuda; K Hisada; N Tonami; H Mori; H Fujii; M Hayashi; S Yamamoto
Journal:  Radiology       Date:  1981-09       Impact factor: 11.105

4.  Single-photon tomographic study of regional cerebral blood flow after stroke: concise communication.

Authors:  F J Bonte; E M Stokely
Journal:  J Nucl Med       Date:  1981-12       Impact factor: 10.057

5.  Initial experience with SPECT (single-photon computerized tomography) of the brain using N-isopropyl I-123 p-iodoamphetamine: concise communication.

Authors:  T C Hill; B L Holman; R Lovett; D H O'Leary; D Front; P Magistretti; R E Zimmerman; S Moore; M E Clouse; J L Wu; T H Lin; R M Baldwin
Journal:  J Nucl Med       Date:  1982-03       Impact factor: 10.057

6.  A comparison of brain imaging with gamma camera, single-photon emission computed tomography, and transmission computed tomography: concise communication.

Authors:  N E Watson; R J Cowan; M R Ball; D M Moody; D W Laster; C D Maynard
Journal:  J Nucl Med       Date:  1980-06       Impact factor: 10.057

7.  Local cerebral blood volume determined by three-dimensional reconstruction of radionuclide scan data.

Authors:  D E Kuhl; M Reivich; A Alavi; I Nyary; M M Staum
Journal:  Circ Res       Date:  1975-05       Impact factor: 17.367

8.  Improved brain scan specificity utilizing 99mTc-pertechnetate and 99mTc(Sn)-diphosphonate.

Authors:  K C Fischer; K A McKusick; H P Pendergrass; M S Potsain
Journal:  J Nucl Med       Date:  1975-08       Impact factor: 10.057

9.  Effects of stroke on local cerebral metabolism and perfusion: mapping by emission computed tomography of 18FDG and 13NH3.

Authors:  D E Kuhl; M E Phelps; A P Kowell; E J Metter; C Selin; J Winter
Journal:  Ann Neurol       Date:  1980-07       Impact factor: 10.422

10.  Epileptic patterns of local cerebral metabolism and perfusion in humans determined by emission computed tomography of 18FDG and 13NH3.

Authors:  D E Kuhl; J Engel; M E Phelps; C Selin
Journal:  Ann Neurol       Date:  1980-10       Impact factor: 10.422

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.