P Rozen, M Gelfond, S Zaltzman, J Baron, T Gilat.
Abstract
The esophagus was evaluated in 15 patients with achalasia by continuous gamma camera imaging following ingestion of a semi-solid meal labeled with 99mTc. The images were displayed and recorded on a simple computerized data processing/display system. Subsequent ciné mode images of esophageal emptying demonstrated abnormalities of the body of the esophagus not reflected by the manometric examination. Computer-generated time-activity curves representing specific regions of interest were better than manometry in evaluating the results of myotomy, dilatation, and drug therapy. Isosorbide dinitrate significantly improved esophageal emptying.Entities:
Mesh:
Substances:
Year: 1982 PMID: 6285414 DOI: 10.1148/radiology.144.3.6285414