Literature DB >> 628194

[Computer system for the automatic analysis of cath-lab data. Reliability of pattern-recognition and measurements (author's transl)].

J Meyer, P Jensch, K Zimmer, P C Braun, K Hagemann, G Platte, W Ameling, S Effert.   

Abstract

The computer-system for the on-line-analysis of hemodynamic data developed in Aachen enables the clinical user to perform the immediate on-line analysis of ECG, pressure-curves and thermo- or dye-dilution-curves in a dialog mode. The procedure of pressure analysis as well as the calculations by the computer for the individual haemodynamic parameters are described. The comparison of the medical-manual evaluation of the pressure curves on paper-registration and the computer results of the same measurement shows a very good correlation for wave-recognitions and wave-measurements for this system, integrated in the daily routine since 24 months. As well in the application of various fluid-filled catheters used in praxis as in tip-manometers it could be proved for the pressure-analysis in the different positions of the heart, that the computer-system produced reliable evaluations for all catheter materials used. The flexible conception of the computer program with its fast adaption to new problems allows its use not only in the clinical routine, but also and especially in the handling of scientific questions in the frame-work of haemodynamic analysis.

Mesh:

Year:  1978        PMID: 628194     DOI: 10.1007/bf01480088

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  14 in total

1.  Automatic analysis of the P-QRS-T complex of the electrocardiogram by digital computer.

Authors:  H V PIPBERGER; F W STALLMAN; A S BERSON
Journal:  Ann Intern Med       Date:  1962-11       Impact factor: 25.391

2.  [Computer evaluation of hemodynamic parameters in aortic valve stenoses].

Authors:  J Meyer; P Jensch; H W Zimmer; P C Braun; G Platte; K Hagemann; W Ameling; S Effert
Journal:  Verh Dtsch Ges Inn Med       Date:  1976

3.  [An interactive multi-programming system for various cardiological tasks (author's transl)].

Authors:  P Jensch; J Meyer; W Ameling; S Effert
Journal:  Biomed Tech (Berl)       Date:  1975-06       Impact factor: 1.411

4.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I.

Authors:  R GORLIN; S G GORLIN
Journal:  Am Heart J       Date:  1951-01       Impact factor: 4.749

5.  [Computer analysis of ECG in clinically and coronarographically confirmed myocardial infarct].

Authors:  J Meyer; G Platte; H W Stühlen; M Rupp; A Stelzer; S Effert
Journal:  Verh Dtsch Ges Inn Med       Date:  1975

6.  A system for on-line computer analysis of data during heart catheterization.

Authors:  H R Warner; R M Gardner; T A Pryor; W C Day; W M Stauffer
Journal:  UCLA Forum Med Sci       Date:  1970

7.  [Automation of heart catheterization].

Authors:  R M Gardner; T A Pryor; V Malerczyck; J Pilarczyck; P Heintzen
Journal:  Z Kreislaufforsch       Date:  1970-04

8.  The on-line analysis of atrial pressures using a digital computer.

Authors:  J D Ridges; W J Sanders; D C Harrison
Journal:  Comput Biomed Res       Date:  1973-04

9.  Real-time analysis of cardiac catheterization data using a computer system.

Authors:  D C Harrison; J D Ridges; W J Sanders; E L Alderman; J A Fanton
Journal:  Circulation       Date:  1971-10       Impact factor: 29.690

10.  [Data processing system for laboratory and hemodynamic heart catheterization measurements].

Authors:  P Jensch; J Meyer; E Mattar; W Ameling; S Effert
Journal:  Z Kardiol       Date:  1976-10