Literature DB >> 6275694

Nuclear magnetic resonance imaging of the liver: initial experience.

F H Doyle, J M Pennock, L M Banks, M J McDonnell, G M Bydder, R E Steiner, I R Young, G J Clarke, T Pasmore, D J Gilderdale.   

Abstract

Nuclear magnetic resonance (NMR) scans of the liver were obtained in 12 normal volunteers and 32 patients using a whole-body machine developed by Thorn-EMI Ltd., and the results were compared with x-ray computed tomography (CT). Two types of NMR scan, saturation-recovery and inversion-recovery, were performed in order to obtain values for the spin-lattice relaxation time, T1. Although the saturation-recovery scans show little soft-tissue detail, the inversion-recovery scans demonstrated the interlobar fissure, hepatic veins, portal veins, bile ducts, and gallbladder. In comparison with CT (Siemens Somatom 2), both types of NMR scan showed some blurring due to respiratory movement but much less linear artifact across the liver from the air-fluid interface in the stomach. Focal disease within the liver was demonstrated by both CT and NMR, although an area of focal atrophy and another of hepatic infarction were only recognized with NMR. In diffuse disease the pattern varied. In steatosis CT was virtually diagnostic, while NMR showed no specific features. In hemochromatosis, hepatitis, eight cases of cirrhosis, and one of Wilson disease, both techniques showed abnormalities of varying specificity. In two cases of cirrhosis and one of primary biliary cirrhosis, only the NMR scan was abnormal. Nuclear magnetic resonance images are now sufficiently anatomically detailed to permit serious comparisons with technically advanced computed tomography. The information revealed is fundamentally different and can be expected to have some diagnostic utility.

Entities:  

Mesh:

Year:  1982        PMID: 6275694     DOI: 10.2214/ajr.138.2.193

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  26 in total

1.  Hepatic iron overload: diagnosis and quantification by noninvasive imaging.

Authors:  J L Chezmar; R C Nelson; J A Malko; M E Bernardino
Journal:  Gastrointest Radiol       Date:  1990

Review 2.  Evaluation of myocardial iron overload using magnetic resonance imaging.

Authors:  Sophie Mavrogeni
Journal:  Blood Transfus       Date:  2009-07       Impact factor: 3.443

3.  Magnetic resonance tomography of the pelvis.

Authors:  F W Smith
Journal:  Cardiovasc Intervent Radiol       Date:  1986       Impact factor: 2.740

4.  A USPIO doped gel phantom for R2* relaxometry.

Authors:  Gregory C Brown; Gary J Cowin; Graham J Galloway
Journal:  MAGMA       Date:  2016-07-19       Impact factor: 2.310

5.  MR imaging in hydatid disease of the liver.

Authors:  F L Hoff; A M Aisen; M E Walden; G M Glazer
Journal:  Gastrointest Radiol       Date:  1987

6.  Magnetic resonance imaging. Part II--Clinical applications.

Authors:  W R Hendee; C J Morgan
Journal:  West J Med       Date:  1984-11

7.  Contributions of Magnetic Resonance Imaging to Gastroenterological Practice: MRIs for GIs.

Authors:  Christopher G Roth; Dina Halegoua-De Marzio; Flavius F Guglielmo
Journal:  Dig Dis Sci       Date:  2018-05       Impact factor: 3.199

8.  Evaluation of focal hepatic masses: a comparative study of MRI and CT.

Authors:  G M Glazer; A M Aisen; I R Francis; B H Gross; J W Gyves; W D Ensminger
Journal:  Gastrointest Radiol       Date:  1986

9.  Focal fatty liver change in a 12-year-old Japanese boy.

Authors:  M Igarashi; Y Akiyama; T Nakamura; S Ohtsuki; Y Nakashima
Journal:  Eur J Pediatr       Date:  1994-06       Impact factor: 3.183

10.  Preliminary findings in the evaluation of hepatic malignancies by radioimmunodetection, X-ray computed tomography, and magnetic resonance imaging.

Authors:  F H DeLand; A Lieber; M D Ram; D M Goldenberg
Journal:  Eur J Nucl Med       Date:  1986
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.