Literature DB >> 626130

Measurement of atrial septal defect during cardiac catheterization. Experimental and clinical results.

T D King, S L Thompson, N L Mills.   

Abstract

The size of experimental and clinical secundum atrial septal defects may be accurately measured during cardiac catheterization. The position of the defects in the septum and their distance from the aortic and mitral valves may also be ascertained. A balloon catheter inflated with radiopaque dye is used for the measurement. The volume of dye in the balloon has been correlated with its maximal diameter. Thus, a no. 8-10 French catheter filled with 10 ml of diatrizoate (50 percent) has a diameter of approximately 25 mm and a no. 8-22 French catheter filled with 40 ml of diatrizoate a diameter of approximately 43 mm. Persistent arrhythmias or other adverse effects of the procedure were not observed. There was a high correlation between balloon-measured atrial septal defects and those measured at necropsy in the animals or at operation in the patients. These measurements aid in determining whether an ostium secundum defect is of proper size and location to be closed transvenously and may also prove valuable in physiologic studies of atrial septal defects or other cardiac anomalies.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 626130     DOI: 10.1016/0002-9149(78)90012-7

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  12 in total

Review 1.  Transcatheter occlusion of cardiac septal defects.

Authors:  P S Rao
Journal:  Indian J Pediatr       Date:  1991 Sep-Oct       Impact factor: 1.967

2.  Transcatheter closure of secundum atrial septal defects with the atrial septal defect occlusion system (ASDOS): initial experience in children.

Authors:  G Hausdorf; M Schneider; B Franzbach; C Kampmann; K Kargus; B Goeldner
Journal:  Heart       Date:  1996-01       Impact factor: 5.994

3.  How to Size ASDs for Percutaneous Closure.

Authors:  Isabelle Boon; Katrien Vertongen; Bernard P Paelinck; Laurent Demulier; An Van Berendoncks; Catherine De Maeyer; Fabienne Marchau; Joseph Panzer; Kristof Vandekerckhove; Daniel De Wolf
Journal:  Pediatr Cardiol       Date:  2017-09-27       Impact factor: 1.655

4.  Impact of intracardiac echocardiography on radiation exposure during adult congenital heart disease catheter-based interventions.

Authors:  Gianluca Rigatelli; Paolo Cardaioli; Loris Roncon; Massimo Giordan; Emiliano Bedendo; Laura Oliva; Stefano Panin; Pietro Zonzin
Journal:  Int J Cardiovasc Imaging       Date:  2006-07-05       Impact factor: 2.357

5.  Atrial septostomy: stationary angioplasty balloon technique--experimental work and preliminary clinical applications.

Authors:  S E Mitchell; J H Anderson; M M Swindle; J D Strandberg; J Kan
Journal:  Pediatr Cardiol       Date:  1994 Jan-Feb       Impact factor: 1.655

Review 6.  Transcatheter occlusion of atrial septal defect and patent ductus arteriosus: now a reality in India.

Authors:  P S Rao
Journal:  Indian J Pediatr       Date:  1993 Sep-Oct       Impact factor: 1.967

7.  Functional and anatomical correlates in atrial septal defect. An echocardiographic analysis.

Authors:  J C Forfar; M J Godman
Journal:  Br Heart J       Date:  1985-08

Review 8.  Surgery without thoracotomy: transcatheter management of pediatric heart disease.

Authors:  P S Rao
Journal:  Indian J Pediatr       Date:  1984 Nov-Dec       Impact factor: 1.967

9.  Extending the limits of transcatheter closure of atrial septal defects with the double umbrella device (CardioSEAL).

Authors:  R Kaulitz; T Paul; G Hausdorf
Journal:  Heart       Date:  1998-07       Impact factor: 5.994

10.  Measurement of Atrial Septal Defect Size: A Comparative Study between Transesophageal Echocardiography and Balloon Occlusive Diameter Method.

Authors:  Hakimeh Sadeghian; Alimohammad Hajizeinali; Bahareh Eslami; Masoumeh Lotfi-Tokaldany; Mahmood Sheikhfathollahi; Mohammad Sahebjam; Elham Hakki; Arezou Zoroufian; Seyed Ebrahim Kassaian; Mohammad Alidoosti
Journal:  J Tehran Heart Cent       Date:  2010-05-31
View more