Collimation of high energy electron beams.

I Lax, A Brahme.   

Abstract

The collimation of high energy electron beams for radiation therapy is treated with special attention on the contamination of the beam by electrons which ideally should be stopped, but instead are scattered back into the beam through the edge of the collimator. It is demonstrated that the mean energy of these electrons is only 40 per cent of the mean energy in the beam and that the smallest electron contamination is obtained if the material closest to the beam is of high density.

Mesh:

Year:  1980        PMID: 6257038     DOI: 10.3109/02841868009130153

Source DB:  PubMed          Journal:  Acta Radiol Oncol        ISSN: 0349-652X


  6 in total

1.  Comparison between small radiation therapy electron beams collimated by Cerrobend and tubular applicators.

Authors:  Cristina Di Venanzio; Marco Marinelli; Alessia Tonnetti; Gianluca Verona-Rinati; Paolo Bagalà; Maria Daniela Falco; Antonio Stefano Guerra; Maria Pimpinella
Journal:  J Appl Clin Med Phys       Date:  2015-01-08       Impact factor: 2.102

2.  Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy.

Authors:  Mohamad M Alabdoaburas; Jean-Pierre Mege; Jean Chavaudra; Jérémi Vũ Bezin; Atilla Veres; Florent de Vathaire; Dimitri Lefkopoulos; Ibrahima Diallo
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

3.  Tungsten filled 3D printed field shaping devices for electron beam radiation therapy.

Authors:  Lawrie Skinner; Benjamin P Fahimian; Amy S Yu
Journal:  PLoS One       Date:  2019-06-19       Impact factor: 3.240

4.  Nontarget and Out-of-Field Doses from Electron Beam Radiotherapy.

Authors:  Natalia Matuszak; Marta Kruszyna-Mochalska; Agnieszka Skrobala; Adam Ryczkowski; Piotr Romanski; Igor Piotrowski; Katarzyna Kulcenty; Wiktoria Maria Suchorska; Julian Malicki
Journal:  Life (Basel)       Date:  2022-06-08

5.  Radiation leakage dose from Elekta electron collimation system.

Authors:  Garrett M Pitcher; Kenneth R Hogstrom; Robert L Carver
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

6.  A dosimetric comparison of copper and Cerrobend electron inserts.

Authors:  Benjamin D Rusk; Robert L Carver; John P Gibbons; Kenneth R Hogstrom
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102