Literature DB >> 624170

Spectral energy of the first heart sound in acute myocardial ischemia. A correlation with electrocardiographic, hemodynamic, and wall motion abnormalities.

W B Clarke, S M Austin, P M Shah, P M Griffin, J T Dove, J McCullough, B F Schreiner.   

Abstract

First heart sound (S1) energy spectra in isovolumic systole, hemodynamics, and angiographic left ventricular wall motion (LVWM) at rest and with atrial pacing were compared in 27 patients who underwent diagnostic cardiac catheterization and angiography because of chest pain. Eighteen patients were found to have coronary artery disease (CAD) and nine patients, normal coronary arteries. Eleven of the 18 CAD patients (61%) had a mean reduction in the spectral energy of S1 of 6.5 +/- 1.4 (SEM) dB below control (-52%), during interruption of ischemic stress of rapid atrial pacing, compared to only one of nine patients without CAD (P less than 0.05). Only five CAD patients (28%) had an abnormal rise (greater than or equal to 5 mm) in left ventricular end-diastolic pressure (LVEDP) either during or upon interruption of pacing, and six (33%) had ischemic ST-segment depression greater than or equal to mv in the ECG. Similarly two patients free of CAD (22%) had an abnormal increase in LVEDP, and none had ECG evidence of ischemia. Seventeen CAD patients (94%) had segmental LVWM abnormalities at rest or with interruption of pacing, while three patients with normal coronary arteries (33%) had abnormal angiographic LVWM (P less than 0.01). Thus, reduction is S1 spectral energy is a common accompaniment of myocardial ischemia. In the present study, it was more frequently observed than abnormalities in either the ECG or LVEDP, but was not was consistently seen as segmental left ventricular wall motion abnormalities.

Entities:  

Mesh:

Year:  1978        PMID: 624170     DOI: 10.1161/01.cir.57.3.593

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  2 in total

1.  Heart sounds analysis via esophageal stethoscope system in beagles.

Authors:  Sang Hi Park; Young Duck Shin; Jin Ho Bae; Eun Jung Kwon; Tae-Soo Lee; Ji-Yun Shin; Yeong-Cheol Kim; Gyeong-Deuk Min; Myoung hwan Kim
Journal:  J Clin Monit Comput       Date:  2013-03-26       Impact factor: 2.502

2.  The correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia.

Authors:  Young Duck Shin; Kyoung Hoon Yim; Sang Hi Park; Yong Wook Jeon; Jin Ho Bae; Tae Soo Lee; Myoung Hwan Kim; Young Jin Choi
Journal:  Pak J Med Sci       Date:  2014-03       Impact factor: 1.088

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.