Literature DB >> 6238427

Vascular access for haemodialysis--experience at Johannesburg Hospital.

G Louridas, J R Botha, L Levien, F J Milne, A M Meyers, J A Myburgh.   

Abstract

Experience with angio-access in patients with chronic end-stage renal failure undergoing haemodialysis, including those with arteriovenous fistulas constructed within the past 3 years, is reviewed. In patients in group 1, 137 fistulas were constructed; the patency rate at 2 years was 66% and at 4 years 47%. Complications were due to thrombosis, aneurysm and poor operative technique. In group 2 fistulas were constructed from synthetic material in 33 patients; the patency rate at 2 years was 44% and at 4 years 36%. Complications were due to thrombosis and sepsis. No correlation was found between raised fibrinogen levels and fistula or graft failures. Dialysis needles of different gauges were compared; the 16-gauge Terumo needle was found to cause no hemolysis and was adequate for use in dialysis.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6238427

Source DB:  PubMed          Journal:  S Afr Med J


  1 in total

1.  PTFE grafts for hemodialysis access. Techniques for insertion and management of complications.

Authors:  S Raju
Journal:  Ann Surg       Date:  1987-11       Impact factor: 12.969