Literature DB >> 6238212

Coronary artery bypass for unsuccessful percutaneous transluminal coronary angioplasty.

G J Reul, D A Cooley, G L Hallman, J M Duncan, J J Livesay, O H Frazier, D A Ott, P Angelini, A Massumi, V S Mathur.   

Abstract

Of 518 consecutive patients undergoing percutaneous transluminal coronary angioplasty for 571 coronary lesions, 184 eventually underwent coronary artery bypass because of angioplasty failure. Delayed coronary bypass (1 week to 19 months) was done in 27 patients with no deaths. Immediate bypass was done in 87 patients with two deaths, both of which were caused by further dissection of the artery after angioplasty. Urgent bypass was required in 63 patients who were in unstable condition because of ischemia on the electrocardiogram (52 patients), unrelieved angina (57 patients), or hypotension (13 patients). There was one death in this group. In the remaining seven patients, urgent coronary bypass was done because of cardiac arrest (three deaths). Myocardial complications occurred in 23 of the 70 unstable patients, including the seven patients with cardiac arrest. There were only eight completed myocardial infarctions in the 70 unstable patients and a completed myocardial infarction rate of 11 of 184 (6.0%) overall. In the 10 patients in whom extracorporeal circulation was established within 25 minutes of myocardial insult, mortality and myocardial complications were completely avoided. The remaining patients in the urgent group were placed on cardiopulmonary bypass within 26 to 300 minutes (mean 82 minutes). Operative mortality (3.3%), completed myocardial infarction (6.0%), myocardial infarction in unstable patients (32.9%), postoperative hemorrhage (5.0%), and sternal problems (2.8%) were all significantly different from those in 3,500 consecutive coronary bypasses not following angioplasty, that were done in 1982.

Entities:  

Mesh:

Year:  1984        PMID: 6238212

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  9 in total

1.  Does angioplasty need on site surgical cover? A physician's view.

Authors:  T R Shaw
Journal:  Br Heart J       Date:  1990-07

2.  Entrapped coronary catheter remnants and stents: must they be surgically removed?

Authors:  Konstantin Alexiou; Utz Kappert; Michael Knaut; Klaus Matschke; Sems Malte Tugtekin
Journal:  Tex Heart Inst J       Date:  2006

3.  Acute complications of elective coronary angioplasty: a review of 500 consecutive procedures.

Authors:  G Steffenino; B Meier; L Finci; V Velebit; L von Segesser; B Faidutti; W Rutishauser
Journal:  Br Heart J       Date:  1988-02

4.  Reperfusion through balloon catheter to minimize myocardial infarction during the interval between failed percutaneous transluminal coronary angioplasty and emergency coronary artery bypass grafting.

Authors:  S Kusachi; S Takata; K Iwasaki; O Nishiyama; T Kita; H Namba; T Hata; G Taniguchi; D Saito; S Haraoka
Journal:  Heart Vessels       Date:  1989       Impact factor: 2.037

5.  Clinical experience of emergency coronary artery bypass grafting following failed percutaneous transluminal coronary angioplasty.

Authors:  Y Kioka; L Dallan; S Oliveira; A Jatene
Journal:  Jpn J Surg       Date:  1991-11

6.  Emergency coronary artery surgery after refractory cardiac arrest: a single centre experience.

Authors:  J G Powney; R S Bonser; S Lentini
Journal:  Br Heart J       Date:  1992-05

7.  Flow characteristics of coronary balloon catheters.

Authors:  P Angelini; R Leachman; J Heibig
Journal:  Tex Heart Inst J       Date:  1986-06

Review 8.  Desirability of immediate surgical standby for coronary angioplasty.

Authors:  R D Levy; D H Bennett; N H Brooks
Journal:  Br Heart J       Date:  1991-02

9.  Successful myocardial revascularization and neurologic recovery in a patient with prolonged refractory cardiac arrest and a chronically occluded left internal carotid artery.

Authors:  E A Tovar; C Del Campo; D W Landa; A Borsari
Journal:  Tex Heart Inst J       Date:  1995
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.