Literature DB >> 6233401

Estimates of left-ventricular volumes by equilibrium radionuclide angiography: importance of attenuation correction.

M R Starling, L J Dell'Italia, M L Nusynowitz, R A Walsh, W C Little, A R Benedetto.   

Abstract

To compare the accuracy of attenuated and attenuation-corrected equilibrium radionuclide angiographic (RNA) left ventricular (LV) volume estimates, we studied 23 consecutive patients with biplane contrast cineangiography (CINE). Attenuated RNA end-diastolic (ED) and end-systolic (ES) volumes were calculated from background-corrected ED and ES counts obtained from hand-drawn regions of interest that were normalized to cardiac cycles processed, frame rate, and blood activity. A simple, geometric attenuation correction was performed to obtain attenuation-corrected RNA LV volumes. The attenuated and attenuation-corrected RNA LV EDV estimates correlated with the CINE LV EDVs ; however, the attenuation-corrected RNA LV EDV estimates correlated more closely. Also, the average attenuation-corrected RNA LV EDV did not differ significantly from the mean CINE LV EDV. Attenuated and attenuation-corrected RNA LV ESV estimates also correlated with the CINE LV ESVs , but the attenuation-corrected RNA LV ESV estimates correlated more closely. Also, the average attenuation-corrected RNA LV ESV did not differ significantly from the mean biplane CINE LV ESV.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6233401

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  4 in total

1.  Operator-interactive method for simultaneous measurement of left and right ventricular volumes and ejection fraction by tomographic electrocardiography-gated blood pool radionuclide ventriculography.

Authors:  Ian P Clements; Benjamin Brinkmann; Brian P Mullan; Michael K O'Connor; Jerome F Breen; Christopher G A McGregor
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

2.  Left-ventricle boundary detection from nuclear medicine images.

Authors:  X Dai; W E Snyder; G L Bilbro; R Williams; R Cowan
Journal:  J Digit Imaging       Date:  1998-02       Impact factor: 4.056

3.  Quantitative analysis of cardiac function: comparison of electro-cardiogram dual gated single photon emission tomography, planar radionuclide ventriculogram and contrast ventriculography in the determination of LV volume and ejection fraction.

Authors:  G Ziada; M M Mohamed; N Hayat; A M Yousof; H M Abdel-Dayem; R Bahar; E Higazy
Journal:  Eur J Nucl Med       Date:  1987

4.  Left ventricular volume and ejection fraction determined by gated blood pool emission tomography.

Authors:  S R Underwood; S Walton; P J Laming; P H Jarritt; P J Ell; R W Emanuel; R H Swanton
Journal:  Br Heart J       Date:  1985-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.