Literature DB >> 623012

Termination of ventricular tachycardia with bursts of rapid ventricular pacing.

J D Fisher, R Mehra, S Furman.   

Abstract

Bursts of rapid ventricular pacing used during 573 episodes of ventricular tachycardia in 23 patients terminated 5 12 episodes (89 percent), with burst rates averaging 56 beats/min above the ventricular tachycardia rate, for 5 to 10 captures. Tachycardia was accelerated by pacing bursts to rates below 300 beats/min in 16 episodes (3 percent); 10 of these terminated spontaneously or responded to further bursts. Acceleration of heart rate to more than 300 beats/min or ventricular fibrillation occurred six times (1 percent), each episode requiring direct current cardioversion. Pacing bursts had no effect in 38 instances (7 percent), mostly in patients with terminal cardiogenic shock. Implantable pacemakers delivering bursts of rapid ventricular pacing were placed in two patients who have used these units at home. No deaths were associated with bursts of rapid ventricular pacing, which is an effective, rapid, pleasant alternative to repeated direct current cardioversion and a useful tool during electrophysiologic testing in patients with recurrent tachycardia.

Entities:  

Mesh:

Substances:

Year:  1978        PMID: 623012     DOI: 10.1016/0002-9149(78)90138-8

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

1.  Evaluation of a programming algorithm for the third tachycardia zone in a fourth-generation implantable cardioverter-defibrillator.

Authors:  J J Neglia; R B Krol; I Giorgberidze; P Mathew; C Lewis; A N Munsif; S Saksena
Journal:  J Interv Card Electrophysiol       Date:  1997-02       Impact factor: 1.900

2.  Magnetic resonance imaging in patients with cardiac implantable electronic devices: a single-center prospective study.

Authors:  Mrinal Yadava; Matthew Nugent; Angela Krebsbach; Jessica Minnier; Peter Jessel; Charles A Henrikson
Journal:  J Interv Card Electrophysiol       Date:  2017-07-22       Impact factor: 1.900

3.  Efficacy of a tiered therapy defibrillator system used to treat recurrent ventricular arrhythmias refractory to drugs.

Authors:  A C Rankin; S Zaim; A Powell; B Zaim; R Brooks; B A McGovern; H Garan; J N Ruskin
Journal:  Br Heart J       Date:  1993-07

4.  [Value and risk of programmed ventricular stimulation in patients with chronic recurrent ventricular tachycardia (author's transl)].

Authors:  G Steinbeck; M Manz; B Lüderitz
Journal:  Klin Wochenschr       Date:  1981-02-02

5.  Chronic intermittent tachypacing by an optogenetic approach induces arrhythmia vulnerability in human engineered heart tissue.

Authors:  Marta Lemme; Ingke Braren; Maksymilian Prondzynski; Bülent Aksehirlioglu; Bärbel M Ulmer; Mirja L Schulze; Djemail Ismaili; Christian Meyer; Arne Hansen; Torsten Christ; Marc D Lemoine; Thomas Eschenhagen
Journal:  Cardiovasc Res       Date:  2020-07-01       Impact factor: 10.787

Review 6.  Handling of Ventricular Fibrillation in the Emergency Setting.

Authors:  Zoltán Szabó; Dóra Ujvárosy; Tamás Ötvös; Veronika Sebestyén; Péter P Nánási
Journal:  Front Pharmacol       Date:  2020-01-29       Impact factor: 5.810

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.