Literature DB >> 6222899

Role of radio-aerosol and perfusion lung imaging in early detection of chronic obstructive lung disease.

A Garg, P G Gopinath, J N Pande, J S Guleria.   

Abstract

The efficacy of radio-aerosol and perfusion lung imaging in the early detection of chronic obstructive lung disease was evaluated in 38 subjects. The subjects included 5 non-smokers, 21 smokers with minimal or no respiratory symptoms and 12 patients with chronic obstructive lung disease. Each subject consented to a respiratory questionnaire, detailed physical examination, chest X-ray examinations, detailed pulmonary function tests and 99mTc-radio aerosol-inhalation lung imaging. Perfusion lung imaging with 99mTc-labelled macroaggregated albumin was performed in 22 subjects. A significant correlation (P less than 0.001) was observed between the degree of abnormalities on radio-aerosol imaging and pulmonary function tests (PFTs) including forced expiratory volume in 1 s, maximum mid-expiratory flow rate and mean transit time analysis. Abnormal radio-aerosol patterns and deranged PFTs were observed in 21 subjects each. Of 21 subjects with abnormal radioaerosol pattern 8 had normal PFTs. Of 21 subjects with abnormal PFTs 8 had normal aerosol images. Aerosol lung images and PFTs were abnormal more frequently than perfusion lung images. The results suggest that radio-aerosol lung imaging is as sensitive an indicator as PFTs for early detection of chronic obstructive lung disease and can be usefully combined with PFTs for early detection of alteration in pulmonary physiology in smokers.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6222899     DOI: 10.1007/bf00252889

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  8 in total

1.  Respiratory function tests; normal values at median altitudes and the prediction of normal results.

Authors:  H I GOLDMAN; M R BECKLAKE
Journal:  Am Rev Tuberc       Date:  1959-04

2.  The pulmonary diffusing capacity in normal subjects.

Authors:  D V BATES; N G BOUCOT; A E DORMER
Journal:  J Physiol       Date:  1955-08-29       Impact factor: 5.182

3.  A comparison of pulmonary function in male smokers and nonsmokers.

Authors:  M Tockman; H Menkes; B Cohen; S Permutt; J Benjamin; W C Ball; J Tonascia
Journal:  Am Rev Respir Dis       Date:  1976-10

Review 4.  The assessment of airflow obstruction. Role of measurements of airways resistance and of tests of forced expiration.

Authors:  N B Pride
Journal:  Br J Dis Chest       Date:  1971-07

5.  Frequency dependence of compliance as a test for obstruction in the small airways.

Authors:  A J Woolcock; N J Vincent; P T Macklem
Journal:  J Clin Invest       Date:  1969-06       Impact factor: 14.808

6.  Improved radioaerosol administration system for routine inhalation lung imaging.

Authors:  M Hayes; G V Taplin; S K Chopra; D E Knox; D Elam
Journal:  Radiology       Date:  1979-04       Impact factor: 11.105

7.  Effective time of the forced expiratory spirogram in health and airways obstruction.

Authors:  J Jordanoglou; E Koursouba; C Lalenis; T Gotsis; J Kontos; C Gardikas
Journal:  Thorax       Date:  1979-04       Impact factor: 9.139

8.  Early detection of chronic obstructive pulmonary disease using radionuclide lung-imaging procedures.

Authors:  G V Taplin; D P Tashkin; S K Chopra; O E Anselmi; D Elam; B Calvarese; A Coulson; R Detels; S N Rokaw
Journal:  Chest       Date:  1977-05       Impact factor: 9.410

  8 in total
  5 in total

1.  EANM guidelines for ventilation/perfusion scintigraphy : Part 1. Pulmonary imaging with ventilation/perfusion single photon emission tomography.

Authors:  M Bajc; J B Neilly; M Miniati; C Schuemichen; M Meignan; B Jonson
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-08       Impact factor: 9.236

2.  Quantitative analysis of radioaerosol inhalation and perfusion scintigraphy in dogs.

Authors:  W E van den Brom; C Clercx; A J van Toor; H W de Vries
Journal:  Lung       Date:  1989       Impact factor: 2.584

3.  Tracers for aerosol ventilation scintigraphy: Tc-99m versus In-113m.

Authors:  P Wollmer; L Andersson; L Eriksson
Journal:  Eur J Nucl Med       Date:  1987

4.  Joint Guideline on Venous Thromboembolism - 2022.

Authors:  Ana Cristina Lopes Albricker; Cláudia Maria Vilas Freire; Simone Nascimento Dos Santos; Monica Luiza de Alcantara; Mohamed Hassan Saleh; Armando Luis Cantisano; José Aldo Ribeiro Teodoro; Carmen Lucia Lascasas Porto; Salomon Israel do Amaral; Orlando Carlos Gloria Veloso; Ana Cláudia Gomes Pereira Petisco; Fanilda Souto Barros; Márcio Vinícius Lins de Barros; Adriano José de Souza; Marcone Lima Sobreira; Robson Barbosa de Miranda; Domingos de Moraes; Carlos Gustavo Yuji Verrastro; Alexandre Dias Mançano; Ronaldo de Souza Leão Lima; Valdair Francisco Muglia; Cristina Sebastião Matushita; Rafael Willain Lopes; Artur Martins Novaes Coutinho; Diego Bromfman Pianta; Alair Augusto Sarmet Moreira Damas Dos Santos; Bruno de Lima Naves; Marcelo Luiz Campos Vieira; Carlos Eduardo Rochitte
Journal:  Arq Bras Cardiol       Date:  2022-04       Impact factor: 2.000

5.  Krypton-81m and 5-micron radioaerosol images in asymptomatic asthma: a blind marking assessment.

Authors:  J E Agnew; E J Wood; P P Sutton; J R Bateman; D Pavia; S W Clarke
Journal:  Eur J Nucl Med       Date:  1984
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.