Literature DB >> 6219424

Feasibility of gated single-photon emission transaxial tomography of the cardiac blood pool.

J Maublant, P Bailly, D Mestas, J Cassagnes, J R Lusson, S Zurowski, E Huffer, A Veyre, H Jallut, G Meyniel.   

Abstract

A procedure for gated single-photon emission transaxial tomography of the cardiac blood pool using a commercially available rotating camera and a computer is described. During image acquisition, the end-diastolic and end-systolic frames are retained after each of the 16 angular steps of the rotation of the camera around the anterior side of the patient's chest. Complete acquisition takes 25 minutes; 10 more minutes are required for the reconstruction and processing of the sections. One set of images is oriented transaxially; the other set includes vertical sections obtained by rotation around a vertical axis passing through the center of the left ventricular cavity. Results from the planar and tomographic examinations were in good agreement for most of the 18 patients who underwent both studies, although more inferior abnormalities were detected with tomography.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6219424     DOI: 10.1148/radiology.146.3.6219424

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  8 in total

1.  A historical perspective on measurement of ventricular function with scintigraphic techniques: Part II--Ventricular function with gated techniques for blood pool and perfusion imaging.

Authors:  Kim A Williams
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

2.  Potential added value of three-dimensional reconstruction and display of single photon emission computed tomographic gated blood pool images.

Authors:  E H Botvinick; J W O'Connell; P P Kadkade; S L Glickman; M W Dae; T J Cohen; J Abbott; R Krishnan
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

3.  Tomographic radionuclide ventriculography: opportunity ignored?

Authors:  J R Corbett
Journal:  J Nucl Cardiol       Date:  1994 Nov-Dec       Impact factor: 5.952

Review 4.  Clinical applications of SPECT.

Authors:  J W Keyes
Journal:  Int J Card Imaging       Date:  1989

5.  Quantitative analysis of cardiac function: comparison of electro-cardiogram dual gated single photon emission tomography, planar radionuclide ventriculogram and contrast ventriculography in the determination of LV volume and ejection fraction.

Authors:  G Ziada; M M Mohamed; N Hayat; A M Yousof; H M Abdel-Dayem; R Bahar; E Higazy
Journal:  Eur J Nucl Med       Date:  1987

Review 6.  Cardiac single photon emission computerized tomography: the critical period.

Authors:  J B Gill; R H Moore; D D Miller; N Tamaki; T Ruddy; M Barlai-Kovach; C A Boucher; H W Strauss
Journal:  Int J Card Imaging       Date:  1985

7.  Comparison of tomographic and planar radionuclide ventriculography in the assessment of regional left ventricular function in patients with left ventricular aneurysm before and after surgery.

Authors:  P Lu; X Liu; R Shi; L Mo; J S Borer
Journal:  J Nucl Cardiol       Date:  1994 Nov-Dec       Impact factor: 5.952

8.  Quantification of area and percentage of infarcted myocardium by single photon emission computed tomography with thallium-201: a comparison with serial serum CK-MB measurements.

Authors:  T Nakata; T Noto; K Uno; A Wada; N Hikita; S Tanaka; T Shoji; M Kubota; T Tsuda; K Morita
Journal:  Ann Nucl Med       Date:  1989-03       Impact factor: 2.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.