| Literature DB >> 6214671 |
A C Fiore, J W Brown, R S Cromartie, L C Ofstein, P S Peigh, N S Sears, W P Deschner, H King.
Abstract
The superior vena cava (SVC) and thoracic inferior vena cava (IVC) were replaced in 46 dogs with autologous vein, knitted Dacron, glutaraldehyde-fixed porcine pericardium, unsupported polytetrafluorethylene (PTFE), and externally stented PTFE. After 30 days, patency rates were determined by contrast venography and were 100%, 9%, 50%, 75%, and 100%, respectively. The patency rates of Dacron and glutaraldehyde-fixed pericardium are considered unacceptable when compared to autologous vein (p less than 0.05). Stented PTFE exhibited a patency rate equal to that of autologous vein at 30 days, minimal graft reaction, excellent incorporation by host fibroblasts, and a smooth neointima. The external spiral support added to PTFE enchanced the thromboresistance of this graft in the thoracic venous system. Long-term follow-up is required to determine if the stented PTFE prosthesis remains comparable to autologous vein as a venous conduit.Entities:
Mesh:
Substances:
Year: 1982 PMID: 6214671
Source DB: PubMed Journal: J Thorac Cardiovasc Surg ISSN: 0022-5223 Impact factor: 5.209