Literature DB >> 6192522

Composite pericardial monocusp patch for the reconstruction of right ventricular outflow tract. Clinical application in 7 patients.

J M Revuelta, J L Ubago, C M Durán.   

Abstract

Right ventricular outflow tract (RVOT) reconstruction with a new composite pericardial monocusp patch incorporating a sinus of Valsalva was performed in 7 patients. There was one hospital death. Follow-up ranged from 20 to 52 months (mean 25.4 months, cumulatively 206 patient months). Four patients have been recatheterized at an average of 6.5 months (1 to 12 months) after surgery. The average RVOT gradient was 9 +/- 2 mmHg, and mean right ventricular end-diastolic pressure was 10 +/- 5.5 mmHg. All except one have a competent pulmonary valve with normally functioning monocusp, and no thrombosis, calcification or aneurysmal dilatation.

Entities:  

Mesh:

Year:  1983        PMID: 6192522     DOI: 10.1055/s-2007-1021967

Source DB:  PubMed          Journal:  Thorac Cardiovasc Surg        ISSN: 0171-6425            Impact factor:   1.827


  2 in total

Review 1.  Tetralogy of fallot: yesterday and today.

Authors:  Joanne P Starr
Journal:  World J Surg       Date:  2010-04       Impact factor: 3.352

2.  Reconstruction of the right ventricular outflow tract with bovine pericardial monocusp patch.

Authors:  L Lukács L; B Záborszky B; K Sárközy K; A Arvay
Journal:  Tex Heart Inst J       Date:  1984-09
  2 in total