Literature DB >> 6190637

Removal of eye movement and ECG artifacts from the non-cephalic reference EEG.

C Fortgens, M P De Bruin.   

Abstract

A method is described that automatically eliminates eye movement artifacts from EEG records and creates an extracranial reference electrode in one single process. The usefulness of this method is illustrated for both standard EEG recording as well as for CNV and P300 potentials. The artifact signals are measured with a special set of electrodes and are combined in order to subtract the artifacts from contaminated EEG records. The subtraction ratios are determined as those that minimize the variance in the result corrected EEG signal.

Entities:  

Mesh:

Year:  1983        PMID: 6190637     DOI: 10.1016/0013-4694(83)90010-x

Source DB:  PubMed          Journal:  Electroencephalogr Clin Neurophysiol        ISSN: 0013-4694


  9 in total

Review 1.  The removal of ocular artefacts from the electroencephalogram: a review.

Authors:  B W Jervis; E C Ifeachor; E M Allen
Journal:  Med Biol Eng Comput       Date:  1988-01       Impact factor: 2.602

2.  Contingent negative variation in adults with Gilles de la Tourette syndrome.

Authors:  T C van Woerkom; C Fortgens; B J van de Wetering; C M Martens
Journal:  J Neurol Neurosurg Psychiatry       Date:  1988-05       Impact factor: 10.154

3.  Investigation and comparison of some models for removing ocular artefacts from EEG signals. Part 2. Quantitative and pictorial comparison of models.

Authors:  E C Ifeachor; B W Jervis; E M Allen; E L Morris; D E Wright; N R Hudson
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

4.  Investigation and comparison of some models for removing ocular artefacts from EEG signals. Part 1. Review of models and data analysis.

Authors:  E C Ifeachor; B W Jervis; E M Allen; E L Morris; D E Wright; N R Hudson
Journal:  Med Biol Eng Comput       Date:  1988-11       Impact factor: 2.602

5.  New online method for removing ocular artefacts from EEG signals.

Authors:  E C Ifeachor; B W Jervis; E L Morris; E M Allen; N R Hudson
Journal:  Med Biol Eng Comput       Date:  1986-07       Impact factor: 2.602

6.  New spectral detection and elimination test algorithms of ECG and EOG artefacts in neonatal EEG recordings.

Authors:  H Witte; S Glaser; M Rother
Journal:  Med Biol Eng Comput       Date:  1987-03       Impact factor: 2.602

7.  Computerized pattern recognition of EEG artifact.

Authors:  D J MacCrimmon; G J Durocher; R W Chan; D R Hay; B M Saxena
Journal:  Brain Topogr       Date:  1993       Impact factor: 3.020

8.  On-line method for enhancement of electroencephalogram signals in presence of electro-oculogram artefacts using nonlinear recursive least squares technique.

Authors:  K D Rao; D C Reddy
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

9.  Effect on EEG responses of removing ocular artefacts by proportional EOG subtraction.

Authors:  B W Jervis; M Coelho; G W Morgan
Journal:  Med Biol Eng Comput       Date:  1989-09       Impact factor: 2.602

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.