Literature DB >> 618400

Improved efficiency of treadmill exercise testing using a multiple lead ECG system and basic hemodynamic exercise response.

B R Chaitman, M G Bourassa, P Wagniart, F Corbara, R J Ferguson.   

Abstract

One hundred consecutive men with a normal ECG at rest had a maximal treadmill test using 14 leads during and post-exercise. Coronary arteriography performed the following day revealed coronary stenoses greater than or equal to 70% in 66 patients. Test results obtained from a V5 lead were compared to different lead combinations and were correlated with arteriographic findings. A positive exercise test occurred in 37 men using an isolated V5 lead compared to 50 men (P less than 0.05) using 11 leads, 52 men (P less than 0.05) using a combined CM5, CC5, Cl (inferior) lead system and 58 (P less than 0.001) men using all 14 leads. The predictive value of a positive test varied between 89-95% and was not changed significantly by the addition of multiple leads. The 14 lead ECG was positive in 43/45 (96%) patients with multivessel disease. Parameters which helped to predict multivessel disease using 14 leads were 1) the time that ischemia first appeared 2) the pressure-rate product at the time ischemia first appeared, and 3) the maximum workload that could be attained. In general, the magnitude of ST-segment depression and the time required for a positive ECG to return to normal postexercise were not useful predictors of multivessel disease. We conclude that the use of multiple leads improves the sensitivity and efficiency of the maximal treadmill exercise test. The usefulness of exercise test results can be further improved if multiple leads are combined with physiologic data collected during exercise.

Entities:  

Mesh:

Year:  1978        PMID: 618400     DOI: 10.1161/01.cir.57.1.71

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  15 in total

Review 1.  Intraoperative automated ST segment analysis: a reliable 'black box'?

Authors:  H Yang
Journal:  Can J Anaesth       Date:  1996-10       Impact factor: 5.063

Review 2.  Stress testing. Directions for the future.

Authors:  C Foster
Journal:  Sports Med       Date:  1988-07       Impact factor: 11.136

3.  Evaluation of the exercise electrocardiogram by the ST segment/heart rate slope.

Authors:  P Kligfield; O Ameisen; P M Okin; J S Borer
Journal:  Bull N Y Acad Med       Date:  1987-06

4.  Value of the bipolar lead CM5 in electrocardiography.

Authors:  A A Quyyumi; T Crake; L J Mockus; C A Wright; A F Rickards; K M Fox
Journal:  Br Heart J       Date:  1986-10

5.  Left ventricular volume determined by radionuclide techniques: a review.

Authors:  J F Tubau
Journal:  West J Med       Date:  1981-08

6.  Diagnostic value of routine exercise testing in hospital patients with angina pectoris.

Authors:  J A Raffo; I Y Luksic; C T Kappagoda; D A Mary; J B Stoker; W Whitaker; R J Linden
Journal:  Br Med J       Date:  1979-08-04

7.  Accurate detection of coronary heart disease by new exercise test.

Authors:  M S Elamin; R Boyle; M M Kardash; D R Smith; J B Stoker; W Whitaker; D A Mary; R J Linden
Journal:  Br Heart J       Date:  1982-10

8.  Significance of lead strength during exercise testing.

Authors:  George Polizos; Myrvin H Ellestad
Journal:  Ann Noninvasive Electrocardiol       Date:  2007-01       Impact factor: 1.468

9.  Early postoperative myocardial morbidity in patients with coronary artery disease undergoing major non-cardiac surgery: correlation with perioperative ischaemia.

Authors:  R D Seegobin; T H Wilmshurst; J Johnston; F Clewlow; A Murrills; A H Seegobin; F Goodland; C Wainwright; J Norman; N Conway
Journal:  Can J Anaesth       Date:  1991-11       Impact factor: 5.063

10.  Detection of high risk coronary artery disease by thallium imaging.

Authors:  M J O'Hara; A Lahiri; J R Whittington; J C Crawley; E B Raftery
Journal:  Br Heart J       Date:  1985-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.