Literature DB >> 6182859

The efficiency of the Sudan-III-staining to identify wear particles of pmma-bone cement in tissue after total endoprostheses.

F Lintner, P Bösch, G Brand.   

Abstract

On the basis of the newly-formed capsular tissue of 80 cemented (Weber-Huggler, Müller-Charnley) and uncemented (ceramic/ceramic/titanium) total hip endoprostheses which had to be reoperated on because of aseptic loosening, the efficiency of the Sudan-III-staining reported in literature to identify polymethylmethacrylate (PMMA) bone cement particles is investigated, because the quantity as well as quality of the various wear products is discussed as possible factors of prostheses loosening. PMMA-, polyethylene and polyester particles show definite sudanophilia and orange-red coloration in the Sudan-III-stained frozen sections, so that only very large wear products utilizing the knowledge of the materials of the artificial joints used can be recognized by their forms, whereas the wear stored in the macrophages cannot be identified. Thus, Sudan-III-staining is not suitable for guaranteeing identification and determination of the amount of PMMA-wear.

Entities:  

Mesh:

Substances:

Year:  1982        PMID: 6182859     DOI: 10.1007/bf00462343

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0344-8444


  8 in total

1.  Identification of wear particles in tissue after implantation of different plastic materials.

Authors:  H J Leugering; H Püschner
Journal:  J Biomed Mater Res       Date:  1978-07

2.  [Clinical, radiological and histological investigations in loosened total hip replacements (author's transl)].

Authors:  K E Brinkmann; K Heilmann
Journal:  Arch Orthop Unfallchir       Date:  1974

3.  Total surface hip replacement in the dog. A preliminary study of local tissue reaction.

Authors:  D G Mendes; P S Walker; F Figarola; P G Bullough
Journal:  Clin Orthop Relat Res       Date:  1974-05       Impact factor: 4.176

4.  Identification of acrylic cement particles in tissues.

Authors:  R B Pedley; G Meachim; T Gray
Journal:  Ann Biomed Eng       Date:  1979       Impact factor: 3.934

5.  [Histological examinations of remodelling proceedings on the cement-bone surface of endoprosthesis after implantation from 3-10 years ].

Authors:  F Lintner; P Bösch; G Brand
Journal:  Pathol Res Pract       Date:  1982       Impact factor: 3.250

6.  Histochemical and histophysical detection of wear products resulting from prostheses.

Authors:  L Józsa; A Réffy
Journal:  Folia Histochem Cytochem (Krakow)       Date:  1980

7.  [Surface structures of bone cement].

Authors:  H G Willert; G Buchhorn; L Zichner; K Müller; M Semlitsch
Journal:  Z Orthop Ihre Grenzgeb       Date:  1979-08

8.  Polymeric debris in synovium after total joint replacement: histogical identification.

Authors:  A Crugnola; A Schiller; E Radin
Journal:  J Bone Joint Surg Am       Date:  1977-10       Impact factor: 5.284

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.