Literature DB >> 6168222

Detection of Mycoplasma bovis specific IgG in bovine serum by enzyme-linked immunosorbent assay.

J T Boothby, D E Jasper, M H Rollins, C B Thomas.   

Abstract

The enzyme-linked immunosorbent assay (ELISA) was optimized for detection of Mycoplasma bovis-specific IgG in bovine serum. The test is rapid, reproducible, convenient, and sensitive. With this assay, the serum from naturally infected and immunized calves demonstrated the presence of antibodies early in infection and rapid increase in titers during the infection. Cross-reactivity of bovine serum with mycoplasma antigens of bovine, caprine, avian, and environmental sources was tested with this assay system. Cross-reaction was measurable in all instances, with the strongest reaction measured between M bovis and M agalactiae.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 6168222

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  6 in total

1.  Experimental intramammary inoculation with Mycoplasma bovis in vaccinated and unvaccinated cows: effect on milk production and milk quality.

Authors:  J T Boothby; D E Jasper; C B Thomas
Journal:  Can J Vet Res       Date:  1986-04       Impact factor: 1.310

2.  Development of a recombinant protein-based enzyme-linked immunosorbent assay for diagnosis of Mycoplasma bovis infection in cattle.

Authors:  Nadeeka K Wawegama; Glenn F Browning; Anna Kanci; Marc S Marenda; Philip F Markham
Journal:  Clin Vaccine Immunol       Date:  2013-12-11

3.  Experimental intramammary inoculation with Mycoplasma bovis in vaccinated and unvaccinated cows: effect on local and systemic antibody response.

Authors:  J T Boothby; D E Jasper; C B Thomas
Journal:  Can J Vet Res       Date:  1987-01       Impact factor: 1.310

4.  Epidemiological study of enzootic pneumonia in dairy calves in Saskatchewan.

Authors:  J Van Donkersgoed; C S Ribble; L G Boyer; H G Townsend
Journal:  Can J Vet Res       Date:  1993-10       Impact factor: 1.310

5.  Measurement of antibody to Ureaplasma urealyticum by an enzyme-linked immunosorbent assay and detection of antibody responses in patients with nongonococcal urethritis.

Authors:  M B Brown; G H Cassell; D Taylor-Robinson; M C Shepard
Journal:  J Clin Microbiol       Date:  1983-02       Impact factor: 5.948

6.  Applications of enzyme-linked immunosorbent assay in veterinary medicine: a bibliography.

Authors:  S Charan; O P Gautam
Journal:  Vet Res Commun       Date:  1984-11       Impact factor: 2.459

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.