Literature DB >> 6160506

The small-tined pacemaker lead--absence of dislodgement.

H Mond, G Sloman.   

Abstract

The Medtronic 6961 unipolar transvenous ventricular lead has four symmetrically placed, small tines that protrude backward just proximal to the tip, and are designed to become entrapped beneath or between right ventricular trabeculae. One hundred leads were implanted. Initially, the leads were more difficult to position at the right ventricular apex as the tines tended to anchor on intracardiac structures. This was overcome by rotating the lead. The time of negotiating the lead from right atrium to right ventricular apex averaged 3.1 minutes for all leads. The first 20 procedures averaged 4.2 minutes and the last 20 averaged 2.1 minutes. In this latter group, 11 of the 20 passages took 60 seconds or less. Once adequate positioning was obtained, the lead was retracted using slight tension to demonstrate tip entrapment. There were no lead dislodgements. Eight deaths occurred following institution of pacing and lead dislodgement was not detected in any of these cases. Four patients had complications associated with pacing, two transient diaphragmatic pacing not requiring reoperation, one right ventricular perforation and one raised threshold with intermittent failure of pacing without lead perforation or dislodgement. Because of the absence of dislodgement, this lead appears to have significant advantages over conventional leads.

Entities:  

Mesh:

Year:  1980        PMID: 6160506     DOI: 10.1111/j.1540-8159.1980.tb04326.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  [Removal of the endocardial pacemaker leads--experience with 16 leads in 10 patients].

Authors:  S Hasegawa; T Morimoto; N Matsuyama; J Okamoto; Y Sawada; K Kondo; K Asada; S Sasaki
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  1998-05

2.  Modern atrial and ventricular leads for permanent cardiac pacing.

Authors:  E J Perrins; R Sutton; B Kalebic; L R Richards; C Morley; B Terpstra
Journal:  Br Heart J       Date:  1981-08

3.  A long-term, prospective, cohort study on the performance of right ventricular pacing leads: comparison of active-fixation with passive-fixation leads.

Authors:  Lie Liu; Jiaojiao Tang; Hu Peng; Shulin Wu; Chunying Lin; Dongli Chen; Qianhuan Zhang; Yuanhong Liang; Silin Chen; Yan Chen; Huiqiang Wei
Journal:  Sci Rep       Date:  2015-01-07       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.