Literature DB >> 6159460

Acrylic spinal fusion. A 20-year clinical series and technical note.

R R Hansebout, G A Blomquist.   

Abstract

Methyl methacrylate (acrylic) was used in fusion techniques in 82 patients, most of whom had metastatic disease, between 1959 and 1979. In all cases the acrylic was used to supplement stabilization with Meurig-Williams stainless steel plates or with wire. In cases involving a decompressive laminectomy and excisional biopsy (radical resection of a tumor mass) that required posterior stabilization, acrylic helped to achieve rapid fusion with excellent results. The series included one anterior fusion with acrylic and nine atlantoaxial fusions in patients without tumors. Strict guidelines for selection of patients are outlined. The advantage of acrylic over bone fusion in selected patients is discussed. Careful follow-up studies including autopsy examinations are included. The technique of the use of acrylic is outlined. There was no case of late instability. There was one instance of infection in a patient who was immunodeficient and in whom a combination acrylic and bone fusion was performed. Tissue reaction to the acrylic in autopsy specimens is discussed.

Entities:  

Mesh:

Substances:

Year:  1980        PMID: 6159460     DOI: 10.3171/jns.1980.53.5.0606

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  7 in total

1.  Vertebral body replacement with homologous femoral head transplants.

Authors:  P Griss; M Pfeiffer
Journal:  Int Orthop       Date:  1991       Impact factor: 3.075

2.  Operative treatment of thoraco-lumbar metastases, using methylmetacrylate and Kempf's rods for vertebral replacement and stabilization. Report of 15 cases.

Authors:  G Lozes; A Fawaz; P Devos; P Wyremblewski; P Kassiotis; H Perper; G Gozet; J P Pruvo; M Jomin
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

3.  Heat generation and heat protection in methylmethacrylate cementation of vertebral bodies. A cadaver study evaluating different clinical possibilities of dural protection from heat during cement curing.

Authors:  S Toksvig-Larsen; R Johnsson; B Strömqvist
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

4.  The acrylic-wire option in cervical spine fixation. A retrospective study.

Authors:  A Raco; N Di Lorenzo; R Delfini; P Ciappetta; G Cantore
Journal:  Acta Neurochir (Wien)       Date:  1993       Impact factor: 2.216

5.  The European Spine Society AcroMed Prize 1994. Acute thermal nerve root injury.

Authors:  S Konno; K Olmarker; G Byröd; C Nordborg; B Strömqvist; B Rydevik
Journal:  Eur Spine J       Date:  1994       Impact factor: 3.134

6.  The use of Harrington's rods in metastatic tumours with spinal cord compression.

Authors:  F Lesoin; K Kabbaj; J Debout; M Jomin; M Lacheretz
Journal:  Acta Neurochir (Wien)       Date:  1982       Impact factor: 2.216

7.  Total body replacement with iliac bone graft and metal plate stabilization in lower cervical spine.

Authors:  E Pásztor; L Lázár; T Benedek; A Gábor; L Kozma; M Dombai
Journal:  Acta Neurochir (Wien)       Date:  1987       Impact factor: 2.216

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.