Literature DB >> 615217

Time controlled computed tomographic angiography.

H Hacker, H Becker.   

Abstract

A technique is described which, by exact timing of injection and computed tomography (CT) scans, allows a high contrast medium concentration in blood (14 mg iodine/ml blood) to be reached for a brief period, sufficient for a fast scan of 5 to 10 sec duration. This scan demonstrates the early perfusion of the vascular bed of the various organs. With serial, fast CT scans of the same section with 30 sec intervals for 3 min, a dynamic investigation of contrast medium distribution in vessels, tissue, and excretory pathways may be obtained. Preliminary experiments indicate the promising usefulness of this type of examination for brain, kidney, pancreas, spleen, liver, and small bowel.

Entities:  

Mesh:

Year:  1977        PMID: 615217     DOI: 10.1097/00004728-197710000-00004

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  9 in total

1.  Dynamic CT of micro- and macroangiopathic states of the cerebrum.

Authors:  J R Jinkins
Journal:  Neuroradiology       Date:  1988       Impact factor: 2.804

2.  Neoplastic encephalopathy: dynamic CT of cerebral gliomata.

Authors:  J R Jinkins
Journal:  Neuroradiology       Date:  1988       Impact factor: 2.804

3.  CT response of brain parenchyma to intravenous contrast injections.

Authors:  P Kalvach; J Jirout
Journal:  Neuroradiology       Date:  1983       Impact factor: 2.804

4.  Timing of exposure in angiographic computed tomography.

Authors:  N Schad; P Schepke; U Rohde; H Schepke; V Schmid; A Breit
Journal:  Cardiovasc Intervent Radiol       Date:  1981       Impact factor: 2.740

5.  Bilateral aneurysms of the juxtasellar segment of the internal carotid artery.

Authors:  M A Haberbeck-Modesto; G Edner; T Greitz
Journal:  Acta Neurochir (Wien)       Date:  1981       Impact factor: 2.216

6.  Perfusion patterns in CT transit studies.

Authors:  H Traupe; W D Heiss; W Hoeffken; K J Zülch
Journal:  Neuroradiology       Date:  1980       Impact factor: 2.804

7.  The characteristics of cerebral meningiomas and surrounding tissues on dynamic CT.

Authors:  J R Jinkins; R N Sener
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

8.  Reversibility of cerebral ischaemia. Dynamic and xenon computed tomography study on ischaemic cerebrovascular disease.

Authors:  H Ujiie; A Oikawa; K Satoh; H Onda; M Kagawa; K Takakura; Y Kakinoki; Y Ono; N Kobayashi
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

9.  Evaluation of hepatic density change by dynamic CT in healthy humans and in patients with chronic liver diseases.

Authors:  S Sugano; T Okajima; S Kubo; Y Yamazaki; Y Sumino; T Abei
Journal:  Dig Dis Sci       Date:  1992-02       Impact factor: 3.199

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.