| Literature DB >> 6151799 |
H D Fux, C Mattheck, P Morawietz, K Spohn.
Abstract
Using a simple model geometry the effect of stress protection in a bone caused by combination with a metal plate is studied. It is found that no global stress protection exists in any case. The stresses in the bone can be higher than in the homogeneous bone without any reinforcement. Therefore, a consideration of any special type of implantation should be done.Entities:
Mesh:
Year: 1984 PMID: 6151799
Source DB: PubMed Journal: Aktuelle Traumatol ISSN: 0044-6173